Evidence map›Paper›PMID 41881591›Full record

ArticleMedical physics2026

CT data harmonization via learned virtual monoenergetic imaging for cross-kV scan translation and radiomics reproducibility.

Shaojie Chang, Joseph R Swicklik, Zhongxing Zhou, Shravani Kharat, Jarod Wellinghoff, Hao Gong, Eric E Williamson, Thomas A Foley, Cynthia H McCollough, Shuai Leng

Abstract read
In one paragraph

Article in Medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Shaojie ChangDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Joseph R SwicklikDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Zhongxing ZhouDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Shravani KharatDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Jarod WellinghoffDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Hao GongDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Eric E WilliamsonDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Thomas A FoleyDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Cynthia H McColloughDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Shuai LengDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.

Funding

Trade-offs in human observer performance, image quality metrics, and patient doseR01EB017095 · NIBIB · MAYO CLINIC ROCHESTER · PI Hao Gong, Cynthia H McCollough · 2012 to 2026
$7.0M
Comprehensive characterization of coronary atherosclerotic disease using photon-counting-detector dual-source CT and its impact on patient managementR01EB028590 · NIBIB · MAYO CLINIC ROCHESTER · PI LENG, SHUAI, MCCOLLOUGH, CYNTHIA H · 2020 to 2023
$2.6M
Overcoming Challenging Clinical Scenarios in Non-invasive Coronary Artery Imaging using Next Generation Photon Counting Detector CT and Artificial IntelligenceR01EB038746 · NIBIB · MAYO CLINIC ROCHESTER · PI Shuai Leng, Cynthia H McCollough · 2026 to 2026
$626k
American Heart Association Postdoctoral Fellowship (https://doi.org/10.58275/AHA.25POST1372972.pc.gr.227349)NIBIB NIH HHS R01 EB017095NIBIB NIH HHS R01 EB028590NIH HHS R01 EB017095NIH HHS R01 EB028590NIH HHS R01 EB038746
6 · The paper itself

Abstract

backgroundRadiomics extracts quantitative imaging features from computed tomography (CT) data for clinical decision-making. However, variations in acquisition parameters-particularly x-ray tube voltage (kV)-introduce non-biological variability in attenuation values, limiting the reproducibility of radiomic features across scanners, protocols, and institutions. PURPOSE: To develop and evaluate a CT dAta harmoNiZAtion framework based on deep learNed vIrTual monoEnergetic imaging (TANZANITE), which leverages the keV flexibility of virtual monoenergetic images (VMIs) to enable cross-kV scan translation and radiomics harmonization.

methodsTANZANITE is a model hub consisting of multiple pre-trained convolutional neural networks (CNNs), each designed to translate VMIs from 1 keV level to another. Phantom-based calibration was first used to determine energy-equivalent (Eff_E) keV levels corresponding to each tube potential (e.g., Eff_E(A) keV for source kV and Eff_E(B) keV for target kV). A CNN trained using 69 120 patches from seven patient cases to map VMIs from Eff_E(A) to Eff_E(B) was selected from the TANZANITE hub and applied directly to clinical CT images acquired at the source kV. This harmonized the images to match the attenuation characteristics of the target kV setting. Evaluation was conducted on independent dual-energy CT datasets acquired at 100/Sn150 kV. Regions of interest (ROIs) were placed in the kidney, liver, and spine to assess CT number consistency and radiomic feature reproducibility. The concordance correlation coefficient (CCC) was calculated across 93 non-shape radiomic features.

resultsAfter TANZANITE processing with 100 kV images, CT numbers in evaluated organs closely matched the Sn150 kV reference values in four testing patient cases. For example, mean kidney CT numbers changed from 320 HU (100 kV) to 156 HU (TANZANITE), approximating the Sn150 kV value of 160 HU. Similar changes were observed in the liver (157-105 HU vs. 104 HU reference) and spine (45-22 HU vs. 19 HU reference). Radiomic reproducibility improved substantially across organs: mean CCC increased from 0.590 to 0.995 in the liver, 0.300 to 0.970 in the kidney, and 0.630 to 0.968 in the spine. Post-TANZANITE, over 98% of features exceeded the stability threshold (CCC ≥ 0.900) in all three representative organs.

conclusionTANZANITE provides a flexible, image-domain harmonization framework by learning the keV-to-keV translation in the VMI domain and applying pre-trained CNNs to clinical kV images. It improves CT number consistency and organ-specific radiomic reproducibility without requiring raw projection data or scanner-specific training. This approach supports consistent quantitative imaging across multiple-kV acquisition protocols, enhancing radiomics reliability in clinical settings.

Indexed as

Image Processing, Computer-AssistedRadiomicsTomography, X-Ray ComputedConvolutional Neural NetworksHumansPhantoms, ImagingReproducibility of ResultsCT harmonizationdeep learningquantitative imagingradiomics reproducibilityvirtual monoenergetic imaging

Identifiers

PMID41881591
PMCPMC13037684

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.