Evidence map›Paper›PMID 41880331›Full record

ArticlePLoS medicine2026

Transformer-based deep learning model for real-time prediction of intraoperative hypotension using dynamic time-series vital signs: A retrospective study.

Shouqiang Zhu, Weihai Shi, Haichuan Qian, Xiaoqiang Tong, Rongliang Hu, Jinhua Bo, Xiaoping Gu

Abstract read
In one paragraph

Article in PLoS medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Shouqiang ZhuDepartment of Anesthesiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China.ORCID https://orcid.org/0000-0003-2021-5781
Weihai ShiDepartment of Anesthesiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China.
Haichuan QianNanjing Qicheng Medical Technology Co., Ltd., Nanjing, China.
Xiaoqiang TongNanjing Qicheng Medical Technology Co., Ltd., Nanjing, China.
Rongliang HuNanjing Qicheng Medical Technology Co., Ltd., Nanjing, China.
Jinhua BoDepartment of Anesthesiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China.
Xiaoping GuDepartment of Anesthesiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China.ORCID https://orcid.org/0000-0002-8218-7299

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe clinical importance of transient intraoperative hypotension (IOH) remains debated, and existing models often rely on high-resolution waveform data that are not routinely available. METHODS AND

findingsWe developed a Transformer-based deep learning model to predict IOH in real time using continuous vital sign time-series data. The model was trained on 319,699 surgical cases from a tertiary hospital in China (2013-2023) and externally validated using an independent dataset from South Korea. Model interpretability was explored through a real-time alert simulation using 10 representative surgical cases from the internal validation cohort, comparing predicted IOH risk trajectories with measured mean arterial pressure (MAP). To assess clinical relevance, a nested cohort study evaluated the association between IOH burden (cumulative MAP ≤65/60/55 mmHg in mmHg·min) and postoperative acute kidney injury (AKI) and acute kidney disease (AKD). The Transformer model achieved strong prediction performance at 5-, 10-, and 15-min horizons (AUCs 0.904, 0.892, 0.882; recall ≥88.3%). Compared with XGBoost, the Transformer had higher recall (internal 5-min recall 0.891 versus 0.737) and substantially better probability calibration (expected calibration error 0.0083 versus 0.0373). XGBoost showed higher overall accuracy and specificity (internal 5-min specificity 0.913 versus 0.723). External validation confirmed comparable discrimination across models and generalizability, with attenuated calibration differences. In alert simulations, predicted IOH risk closely corresponded to MAP fluctuations. IOH burden was significantly associated with postoperative AKI and AKD (MAP ≤65 mmHg: OR per 60 mmHg·min 1.10 (95% CI, [1.02, 1.19]; p = 0.012) for AKI; 1.26 (95% CI, [1.19, 1.33]; p < 0.001) for AKD). The study is limited by its retrospective design, and prospective, multicenter validation is needed to confirm real-time applicability and generalizability of the model.

conclusionsIOH burden is associated with increased risk of postoperative AKI and AKD. The Transformer model prioritizes sensitivity and calibration for short-term IOH prediction, whereas XGBoost emphasizes accuracy and specificity, reflecting different operating characteristics. Prospective, real-time evaluation is needed before clinical implementation.

Indexed as

Deep LearningHypotensionIntraoperative ComplicationsVital SignsAcute Kidney InjuryChinaFemaleHumansMaleMiddle AgedPredictive Learning ModelsRetrospective Studies

Identifiers

PMID41880331
PMCPMC13046278

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.