Evidence map›Paper›PMID 41877843›Full record

Trial reportClinical ophthalmology (Auckland, N.Z.)2026

Aligning the Axis of Toric Intraocular Lens with the Corneal Steep Meridian by Setting SIA at 0 Diopter: A Prospective Randomized Controlled Trial.

Fanqian Song, Jin Xie, Yusu Peng, Honglei Li, Yunhai Dai

Abstract readCase ReportsClinical Trial
In one paragraph

Trial report in Clinical ophthalmology (Auckland, N.Z.), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Fanqian SongEye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, People's Republic of China.ORCID 0000-0002-3509-2529
Jin XieEye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, People's Republic of China.
Yusu PengEye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, People's Republic of China.
Honglei LiEye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, People's Republic of China.ORCID 0000-0002-9782-596X
Yunhai DaiEye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, People's Republic of China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: This study aims to investigate the clinical efficacy of aligning the axis of toric intraocular lens (IOL) with the corneal steep meridian in cataract patients. Methods: This is a prospective randomized controlled trial involving seventy cataract patients who underwent implantation of a Tecnis Toric IOL. Patients were randomly divided into two groups. In the control group, the incision-induced surgically induced astigmatism (SIA) was set at 0.5 D, and the alignment axis was determined using the Tecnis Toric Aspheric IOL Calculator. In the experimental group, incision SIA was set as 0 D and the alignment axis was aligned with the steep meridian of corneal astigmatism. Primary outcome measures, including astigmatism vector analysis, incision SIA and error of refractive astigmatism (ERA) were analyzed. Visual acuity, predicted residual astigmatism (PRA) and residual astigmatism were evaluated at 3 months. Results: Measurements of postoperative uncorrected and corrected distance visual acuity (UDVA and CDVA), degrees of lens dislocation (°), incision-induced SIA, target induced astigmatism vector and actual surgically induced astigmatism showed no differences between the two groups (P > 0.05). The ERA of the experimental group (0.15 ± 0.32 D) was significantly smaller than the control group (0.58 ± 0.48 D) (P < 0.001). Vector analysis of total error vector (EV) was smaller in the experimental group (0.30 ± 0.24 D) than the control group (0.60 ± 046 D) (P = 0.001). The experimental group showed lower postoperative cylinder (0.49 ± 0.23 D) than the control group (0.71 ± 0.49 D) (P = 0.055). Conclusion: This study suggests that aligning the toric IOL axis with the corneal steep meridian showed by setting SIA as 0 D might be an available method to reduce the error of refractive astigmatism.

Indexed as

astigmatism correctioncataract surgerycorneal steep axistoric intraocular lens

Identifiers

PMID41877843
PMCPMC13006372

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.