Evidence map›Paper›PMID 41877726›Full record

ArticleEuropean heart journal. Case reports2026

The edge-to-edge repair of the iatrogenic torrential tricuspid regurgitation complicating transvenous pacemaker lead extraction: a case series.

Jarosław Skowroński, Adam Rdzanek, Patrycjusz Stokłosa, Krzysztof Jaworski, Piotr Scisło, Agnieszka Kapłon-Cieślicka, Joanna Zakrzewska, Jerzy Pręgowski

Abstract readCase Reports
In one paragraph

Article in European heart journal. Case reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jarosław SkowrońskiNational Institute of Cardiology, ul. Alpejska 42, 04-628 Warsaw, Poland.ORCID https://orcid.org/0000-0001-5561-0656
Adam Rdzanek1st Chair and Department of Cardiology, Medical University of Warsaw, ul. Banacha 1A, 02-091 Warsaw, Poland.
Patrycjusz StokłosaNational Institute of Cardiology, ul. Alpejska 42, 04-628 Warsaw, Poland.
Krzysztof JaworskiNational Institute of Cardiology, ul. Alpejska 42, 04-628 Warsaw, Poland.ORCID https://orcid.org/0000-0001-7128-8812
Piotr Scisło1st Chair and Department of Cardiology, Medical University of Warsaw, ul. Banacha 1A, 02-091 Warsaw, Poland.
Agnieszka Kapłon-Cieślicka1st Chair and Department of Cardiology, Medical University of Warsaw, ul. Banacha 1A, 02-091 Warsaw, Poland.
Joanna ZakrzewskaNational Institute of Cardiology, ul. Alpejska 42, 04-628 Warsaw, Poland.
Jerzy PręgowskiNational Institute of Cardiology, ul. Alpejska 42, 04-628 Warsaw, Poland.ORCID https://orcid.org/0000-0003-1069-554X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: New tricuspid regurgitation (TR) or worsening of baseline pathology may appear after transvenous pacemaker lead extraction (TLE). In case of severe TR induced by TLE, surgical correction might be required. However, the patients in whom TLE is performed are not always appropriate candidates for open-heart intervention. Case Summary: Herein, we present four patients with iatrogenic TR significantly increased to severe-torrential grade after TLE, who were disqualified from surgery. In three cases, the regurgitation was associated with an avulsion of the papillary muscles or chordae tendineae. In one case, it was likely due to the perforation of the tricuspid leaflet during TLE. Patients were treated with transcatheter tricuspid edge-to-edge repair (T-TEER), in three cases successfully. Discussion: Percutaneous repair of TLE-related TR is feasible and may be a valuable therapeutic option in patients with prohibitive surgical risk. One of the most important factors leading to a T-TEER procedural success is the accurate assessment of the tricuspid regurgitation mechanism. In the fourth case, identification of the underlying regurgitation cause was limited by the image quality in the transoesophageal examination.

Indexed as

Case seriesPacemaker lead extractionTranscatheter edge-to-edge repairtricuspid regurgitation

Identifiers

PMID41877726
PMCPMC13008292

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.