Comparison of 2.2 mm vs. 2.6 mm corneal incisions in phacoemulsification in hard nuclear cataracts: impact on intraoperative energy and postoperative corneal recovery.

Maierdanjiang Ainiwaer, Yingying Hong, Binghe Xiao, Li Ning, Yinghong Ji

Abstract read
In one paragraph

Article in Frontiers in ophthalmology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Maierdanjiang Ainiwaer *Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.
Yingying Hong *Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.
Binghe XiaoEye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.
Li NingEye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.
Yinghong JiEye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: This study sought to evaluate the differential impacts of two corneal incision sizes, 2.2 mm and 2.6 mm, on the utilization of intraoperative ultrasound energy and the subsequent postoperative corneal recovery in patients presenting with hard nuclear cataracts. Methods: A retrospective cohort study was undertaken, encompassing cataract patients classified with nuclear hardness grades III to V according to the Emery-Little classification. Participants were allocated into two groups based on the incision size: 2.2 mm and 2.6 mm. Key metrics, including endothelial cell density (ECD), central corneal thickness (CCT), incisional corneal thickness (ICT), and best-corrected visual acuity (BCVA), were assessed preoperatively and at intervals of 1 day, 1 week, 1 month, and 3 months postoperatively. Additionally, intraoperative phacoemulsification parameters and any complications were documented. Results: The study encompassed a total of 100 eyes, with 50 eyes in each group. No statistically significant differences were detected in cumulative dissipated energy (CDE) or ultrasound time (UST) between the two groups (P > 0.05). Both groups exhibited a significant postoperative decline in ECD (P < 0.05), yet no significant intergroup difference was observed in the magnitude of this reduction (P > 0.05). Central corneal thickness (CCT) and intraocular pressure (ICT) exhibited a statistically significant increase at both 1 day and 1 week postoperatively when compared to baseline measurements (P < 0.05). Notably, the increase in ICT was significantly more pronounced in the 2.2 mm incision group at both time points (P < 0.05). Best-corrected visual acuity (BCVA) showed significant improvement in both groups following surgery (P < 0.05), with no significant intergroup differences observed at any follow-up interval (P > 0.05). Additionally, no significant difference in central corneal edema was detected between the two groups (P > 0.05). Conclusion: The corneal incision size (2.2 mm versus 2.6 mm) did not influence the use of intraoperative ultrasound energy or result in differential corneal endothelial cell loss. However, smaller incisions (2.2 mm) were associated with increased short-term edema at the incision site, potentially impacting early wound healing.

Indexed as

corneal edemacorneal incision sizehard nuclear cataractincisional corneal thicknessphacoemalsification

Identifiers

PMID41877720
PMCPMC13006302

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.