Evidence map›Paper›PMID 41875038›Full record

ArticleJournal of synchrotron radiation2026

High-resolution in-beam video rate imaging with the ClearXCam for synchrotron beamlines.

Tyler M Forgacs, Jesse Brown, Erik M Muller, Erik R Farquhar, Manpuneet Kaur Benipal, Anna Zaniewski

Abstract read
In one paragraph

Article in Journal of synchrotron radiation, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Tyler M ForgacsAdvent Diamond, Inc., 7700 South River Parkway, Tempe, AZ 85284, USA.ORCID 0009-0003-8715-7878
Jesse BrownAdvent Diamond, Inc., 7700 South River Parkway, Tempe, AZ 85284, USA.
Erik M MullerBrookhaven National Laboratory, Upton, NY 11973-5000, USA.
Erik R FarquharCenter for Synchrotron Biosciences, Case Western Reserve University, School of Medicine, 10900 Euclid Avenue, Cleveland, OH 44106, USA.ORCID 0000-0002-6419-038X
Manpuneet Kaur BenipalAdvent Diamond, Inc., 7700 South River Parkway, Tempe, AZ 85284, USA.
Anna ZaniewskiAdvent Diamond, Inc., 7700 South River Parkway, Tempe, AZ 85284, USA.

Funding

DOE Office of Science DE-SC0012704National Science Foundation DBI-1228549National Science Foundation NNCI-ECCS-2025490US Department of Energy SC0019659
6 · The paper itself

Abstract

The ClearXCam detector is a new video rate imaging in-beam monitor based on a diamond sensor. Imaging with 2304 effective pixels is achieved by sequentially biasing one of 48 metal stripes on one side of a diamond sensor, while reading out the current from 48 stripes on the other side of the sensor. This system was characterized for real-time X-ray beam diagnostics at synchrotron beamline 17-BM at the National Synchrotron Light Source II. Significant results include: detection of in-beam structure via the imaging mode, beam focusing in one minute with real-time imaging feedback during a focusing event, linearity over five orders of magnitude, validation of a fast mode operating at 100 Hz, and sub-micron beam-positioning resolution. The system is now available commercially.

Indexed as

beam-positioning monitorbeam profile monitordiamond sensorimaging in beam monitorsynchrotron instrumentation

Identifiers

PMID41875038
PMCPMC13148592

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.