Evidence map›Paper›PMID 41874628›Full record

ArticlePediatric radiology2026

Diagnostic performance of triplanar real-time chest magnetic resonance imaging in preschool children - comparison with dedicated lung magnetic resonance imaging.

Michael Zellner, Julia Geiger, Rahel Heule, Selma Sirin, Srdjan Micic, Elias Seidl, Alexander Moeller, Christian J Kellenberger

Abstract read
PubMed Publisher
In one paragraph

Article in Pediatric radiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Michael ZellnerDepartment of Diagnostic Imaging, University Children's Hospital Zurich, Lenggstrasse 30, 8008, Zurich, Switzerland. michael.zellner@kispi.uzh.ch.
Julia GeigerDepartment of Diagnostic Imaging, University Children's Hospital Zurich, Lenggstrasse 30, 8008, Zurich, Switzerland.
Rahel HeuleChildren's Research Center, University Children's Hospital Zurich, Zurich, Switzerland.
Selma SirinDepartment of Diagnostic Imaging, University Children's Hospital Zurich, Lenggstrasse 30, 8008, Zurich, Switzerland.
Srdjan MicicChildren's Research Center, University Children's Hospital Zurich, Zurich, Switzerland.
Elias SeidlChildren's Research Center, University Children's Hospital Zurich, Zurich, Switzerland.
Alexander MoellerChildren's Research Center, University Children's Hospital Zurich, Zurich, Switzerland.
Christian J KellenbergerDepartment of Diagnostic Imaging, University Children's Hospital Zurich, Lenggstrasse 30, 8008, Zurich, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFast magnetic resonance imaging (MRI) acquisitions with high frame rates can mitigate artefacts caused by physiological motion and bulk patient movement, enabling motion-resolved imaging.

objectiveThis study aims to evaluate the detection performance of triplanar real-time cine fast imaging employing steady-state acquisition (FIESTA), compared to conventional MRI sequences. MATERIALS AND

methodsThis retrospective study included 53 children (median age, 1.9 years; range, 1 day-7.1 years) who underwent clinically indicated 1.5-T chest MRI in sedation between January and December 2024. Findings on triplanar real-time cine FIESTA sequences, acquired in up to 1 min, were compared to the findings obtained by dedicated lung sequences (fast spin echo, zero echo time, perfusion imaging) as reference. Detection of extrapulmonary findings (of the chest wall, diaphragm, pleura, mediastinum), lung parenchymal findings (consolidation, atelectasis, bronchial wall thickening, hyperinflation, cysts), and cardiovascular findings by real-time cine FIESTA are presented with descriptive statistics.

resultsReal-time MRI provided diagnostic, motion-artefact-free thoracic images in the sedated but freely breathing patients. Diaphragmatic motion abnormalities were detected in one out of one case (100%), visible only on real-time cine FIESTA and not on the dedicated static sequences. Pleural effusion was present in 16 out of 17 cases (94%), and mediastinal masses were present in five out of five cases (100%). Lung pathologies, including consolidation and atelectasis, were identified in 40 out of 44 cases (91%). However, bronchial wall thickening was missed in all 20 cases (0%). Hyperinflation or air-filled cysts were detected in four out of four cases (100%). Cardiovascular abnormalities were identified in six out of eight cases (75%).

conclusionsReal-time cine FIESTA imaging demonstrated high accuracy in detecting pleural effusion, pulmonary consolidation, cysts, and gross cardiovascular abnormalities in paediatric patients. However, airway pathologies were not identified. Clinical indications for real-time cine chest MRI need to be defined. Feasibility and performance of real-time imaging in unsedated children warrant further study.

Indexed as

Paediatric imagingPaediatric lungReal‐time imagingSedationThoracic imaging

Identifiers

PMID41874628

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.