Evidence map›Paper›PMID 41872525›Full record

ArticleEuropean journal of pediatrics2026

Comparative evaluation of multimodal large language models for diagnostic accuracy in pediatric electrocardiography: a prospective comparative diagnostic accuracy study.

Uğur Saraç, Ayşe Büşra Paydaş, Mustafa Gençeli, Talha Üstüntaş, Mehtap Yücel, Abdülkerim Çokbiçer, Fatih Şap, Tamer Baysal, Mehmet Burhan Oflaz

Abstract readComparative Study
In one paragraph

Article in European journal of pediatrics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Uğur SaraçDepartment of Pediatric Cardiology, Faculty of Medicine, Necmettin Erbakan University, Konya, Turkey. md.ugursarac@gmail.com.ORCID http://orcid.org/0009-0000-0652-5834
Ayşe Büşra PaydaşDepartment of Pediatric Cardiology, Faculty of Medicine, Necmettin Erbakan University, Konya, Turkey.ORCID http://orcid.org/0000-0001-8002-1087
Mustafa GençeliDepartment of Pediatric Infectious Diseases, Faculty of Medicine, Necmettin Erbakan University, Konya, Turkey.ORCID http://orcid.org/0000-0001-9455-2735
Talha ÜstüntaşDepartment of Pediatrics, Faculty of Medicine, Necmettin Erbakan University, Konya, Turkey.ORCID http://orcid.org/0009-0004-2385-0953
Mehtap YücelDepartment of Public Health, Faculty of Medicine, Necmettin Erbakan University, Konya, Turkey.ORCID http://orcid.org/0000-0001-6091-3205
Abdülkerim ÇokbiçerDepartment of Pediatrics, Faculty of Medicine, Necmettin Erbakan University, Konya, Turkey.ORCID http://orcid.org/0000-0002-8454-5555
Fatih ŞapDepartment of Pediatric Cardiology, Faculty of Medicine, Necmettin Erbakan University, Konya, Turkey.ORCID http://orcid.org/0000-0001-7870-9704
Tamer BaysalDepartment of Pediatric Cardiology, Faculty of Medicine, Necmettin Erbakan University, Konya, Turkey.ORCID http://orcid.org/0000-0001-6145-1831
Mehmet Burhan OflazDepartment of Pediatric Cardiology, Faculty of Medicine, Necmettin Erbakan University, Konya, Turkey.ORCID http://orcid.org/0000-0003-1515-4654

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We evaluated three multimodal LLMs, ChatGPT (GPT-5.2), Gemini 3, and Microsoft Copilot, in pediatric ECG interpretation, focusing on clinically significant abnormalities and emergency arrhythmias with likelihood ratios as primary outcome measures. This prospective comparative diagnostic accuracy study (STARD/STARD-AI) included 264 pediatric patients with 12-lead ECGs (November 2024-November 2025). De-identified images were submitted via standardized zero-shot prompt. Three blinded pediatric cardiologists established the reference diagnosis by majority-vote consensus. Cases were classified as Tier 1 (normal), Tier 2 (abnormal, non-urgent), or Tier 3 (urgent). Two binary endpoints were assessed: clinically significant abnormality (Tier 2 + 3 vs Tier 1) and emergency abnormality (Tier 3 vs Tier 1 + 2). Clinically significant abnormalities were present in 54.5% of patients. AUC values ranged from 0.550 to 0.623, reflecting modest discrimination. For the clinically significant endpoint, + LR values were 2.05 (ChatGPT), 1.26 (Gemini), and 1.21 (Copilot); - LR values were 0.68, 0.55, and 0.81, indicating limited rule-in and insufficient rule-out utility. For the emergency endpoint, Gemini achieved 100% sensitivity (95% CI = 85.1-100.0) with - LR 0.07 (95% CI = 0.00-1.12) in a small subgroup (n = 22); however, specificity of 30.2% and + LR of 1.40 indicate overcalling rather than diagnostic precision. No model achieved clinically meaningful rule-in utility for either endpoint.

conclusionsCurrent multimodal LLMs showed limited diagnostic utility in pediatric ECG interpretation, with + LR values near 1.0 across both endpoints. Standalone deployment is not supported; these tools may at most serve as adjunctive screening aids under clinician oversight. WHAT IS KNOWN: • Deep learning algorithms trained on large ECG datasets perform well in adult populations, but evidence in pediatric ECG interpretation is limited. • General-purpose LLMs show variable accuracy in medical examinations; reliability in subspecialty domains such as pediatric cardiology remains unproven. WHAT IS NEW: • This is the[FCA1] first head-to-head comparative diagnostic accuracy study of multimodal LLMs in pediatric ECG evaluation, using likelihood ratios as primary outcome measures. • All three LLMs showed limited rule-in utility (+LR near 1.0); Gemini achieved potentially meaningful rule-out performance for emergency arrhythmias (-LR = 0.07), but with wide confidence intervals reflecting the small emergency subgroup (n = 22). • Gemini's 100% sensitivity in the emergency subgroup reflects overcalling (specificity 30.2%) consistent with a triage/screening behavior rather than diagnostic precision.

Indexed as

Arrhythmias, CardiacElectrocardiographyLarge Language ModelsAdolescentChildChild, PreschoolFemaleHumansInfantMaleProspective StudiesReproducibility of ResultsSensitivity and SpecificityArrhythmia detectionArtificial intelligenceDiagnostic accuracyLarge language modelsLikelihood ratiosPediatric electrocardiography

Identifiers

PMID41872525
PMCPMC13009043

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.