Evidence map›Paper›PMID 41872486›Full record

ArticleNPJ cardiovascular health2026

Development and preclinical results of a transcatheter aortic valve implant with novel polymeric leaflets.

J Ryan Stanfield, Garrett Johnson, Nelson Belais, Isaac George, Steven Yakubov

Abstract read
In one paragraph

Article in NPJ cardiovascular health, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Innovation and Challenges in Materials for Transcatheter Aortic Valves.Journal of cardiovascular translational research · 2026
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

J Ryan StanfieldUniversity of Utah, Department of Mechanical Engineering, Salt Lake City, UT, USA. Ryan.Stanfield@utah.edu.ORCID http://orcid.org/0009-0005-8265-6867
Garrett JohnsonFoldax, Inc, Salt Lake City, UT, USA.
Nelson BelaisCalifornia Institute of Technology, Pasadena, CA, USA.
Isaac GeorgeNew York Presbyterian Hospital/Columbia University Irving Medical Center, Department of Surgery, New York, NY, USA.
Steven YakubovOhioHealth Riverside Methodist Hospital, Columbus, OH, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Current transcatheter aortic valve implantation (TAVI) systems use glutaraldehyde-fixed tissue leaflets, which are prone to structural valve degeneration. Polymeric valves may improve durability, hemocompatibility, and manufacturability. We designed, produced, and evaluated a self-expanding nitinol-framed TAVI device with siloxane poly(urethane-urea) (SiPUU) leaflets and an electrospun SiPUU skirt. Bench testing included frame fatigue to 200 million cycles, hydrodynamics per ISO 5840-3, and flow visualization using particle image velocimetry. Biocompatibility was assessed per ISO 10993. Preclinical evaluation involved nine ovine implants with serial imaging and histology to 90 days. In vitro tests showed EOAs of 1.3-1.5 cm² and 1.7-2.1 cm² (21 and 24 mm annulus, respectively, simulating under expansion), regurgitant fraction <6%, and preserved coaptation. Six animals completed follow-up with stable hemodynamics, no hemolysis, no PVL at implant, and no calcification at explant. The SiPUU-based TAVI demonstrated favorable durability, hydrodynamics, and biocompatibility, supporting further testing and delivery refinement toward first-in-human evaluation. Clinical Trial: N/A.

Identifiers

PMID41872486
PMCPMC13009250