Evidence map›Paper›PMID 41870476›Full record

ArticleThe Journal of the Acoustical Society of America2026

Performance of a through-transmit aberration correction method for transcranial focused ultrasound: Simulation and experimental evaluation.

Cooper L Donovan, Charles F Caskey

Abstract read
In one paragraph

Article in The Journal of the Acoustical Society of America, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Cooper L DonovanVanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee 37232, USA.ORCID 0009-0002-7259-3581
Charles F CaskeyVanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee 37232, USA.ORCID 0000-0003-4545-4842

Funding

Translating an MR-guided focused ultrasound system for first-in-human precision neuromodulation of pain circuitsUG3NS135551 · NINDS · VANDERBILT UNIVERSITY MEDICAL CENTER · PI CASKEY, CHARLES F, CHEN, LI MIN · 2023 to 2023
$4.4M
Biophysical and Neural Basis of Focused Ultrasound StimulationR01NS126144 · NINDS · VANDERBILT UNIVERSITY MEDICAL CENTER · PI Charles F Caskey, Li Min Chen · 2025 to 2026
$1.7M
NINDS NIH HHS R01 NS126144NINDS NIH HHS UG3 NS135551
6 · The paper itself

Abstract

Transcranial focused ultrasound is a promising neuromodulation tool, but skull-induced aberrations to the ultrasound beam require subject-specific correction. To predict and compensate for aberration, the standard in transcranial focused ultrasound is to perform acoustic simulations based on x-ray computed tomography images of the head. However, computed tomography-based methods face shortcomings due to imaging resolution and uncertainty in acoustic parameter estimates. Relativistic through-transmit (RTT) is a recently proposed imaging-independent method that corrects skull-induced aberrations by comparing through-skull acoustic transmission to free-field signals from two opposing transducer arrays. Although RTT has shown promise, its robustness across subjects and conditions has not been fully characterized. In this work, RTT performance was evaluated in simulation as a function of several parameters in four unique non-human primate subjects using commercial linear phased array transducers operating at 1 and 2 MHz. Simulated results were validated experimentally at 2 MHz. In simulations, RTT restored pressure amplitudes to within 5% of the intended value for three skulls but achieved only 60% of the intended pressure in one, with focal shift ranging 0.4 to 5.5 mm. RTT performance depended on signal-to-noise ratio and physical uncertainties and was markedly impacted by steering. Modifications to RTT are proposed and characterized.

Indexed as

Computer SimulationSkullAnimalsPressureSignal Processing, Computer-AssistedTransducers

Identifiers

PMID41870476
PMCPMC13520834

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.