Evidence map›Paper›PMID 41869489›Full record

ReviewJB & JS open access

Mechanism Failures in Externally Controlled Motorized Intramedullary Lengthening Nails: A Systematic Review.

Egor Kostin, Petros Kitsis, Charalampos Charalampidis, Ioannis Orfanos

Abstract readReview
In one paragraph

Review in JB & JS open access. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Egor KostinMedical School, University of Cyprus, Aglantzia, Nicosia, Cyprus.ORCID https://orcid.org/0009-0001-5724-2102
Petros KitsisDepartment of Orthopaedic Surgery, Nicosia General Hospital, Strovolos, Nicosia, Cyprus.ORCID https://orcid.org/0000-0001-6110-1436
Charalampos CharalampidisMedical School, University of Cyprus, Aglantzia, Nicosia, Cyprus.ORCID https://orcid.org/0009-0005-4215-7385
Ioannis OrfanosDepartment of Orthopaedic Surgery, Nicosia General Hospital, Strovolos, Nicosia, Cyprus.ORCID https://orcid.org/0009-0009-6401-2469

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Externally controlled intramedullary lengthening nails (IMNs) have reduced the soft-tissue morbidity associated with external fixation. However, these complex devices introduce specific risks related to their motorized and telescopic mechanisms. Existing literature often conflates structural fatigue fractures with internal mechanism dysfunction. This systematic review aims to analyze the incidence, etiology, and management of intrinsic mechanism failures in lengthening IMNs. Methods: A comprehensive search of PubMed, Embase, and Scopus was conducted from January 2000 to July 2025 in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 guidelines. The review included human studies reporting mechanism-related failures (e.g., jamming, backtracking, and motor failure) in externally controlled IMNs. Studies describing only structural fatigue fractures or nonexternally controlled devices were excluded (e.g., Intramedullary Skeletal Kinetic Distractor [ISKD]). Data were stratified by implant generation and material. Results: Twenty-nine studies encompassing 2,495 nails were included. The overall reported mechanism-related failure rate was 4.3% (n = 107/2,495). Distinct failure phenotypes emerged based on the implant material. Titanium-alloy nails (PRECICE P1/P2) demonstrated a 4.2% failure rate (n = 74/1,761), predominantly characterized by mechanical jamming or gear slippage due to load-induced yield. Stainless steel nails (STRYDE) exhibited a significantly higher failure rate of 12.9% (n = 12/93), primarily driven by tribocorrosion and biological reactions at the telescopic junction. The FITBONE system had a reported failure rate of 3.3% (n = 21/641). Management required surgical intervention in 97.2% of failure cases, with exchange nailing being the primary salvage strategy (94.4%). Despite the need for reoperation, the target limb length was reportedly achieved in the majority of studies where quantitative outcomes were specified. Conclusion: Mechanism failure in externally controlled lengthening IMNs is a clinically significant complication with a reported incidence of approximately 1 in 24 cases. A material trade-off is evident: Titanium implants are susceptible to mechanical gear yield, whereas stainless steel implants are prone to tribocorrosion-induced failure. While these failures necessitate revision surgery, they typically do not preclude successful limb reconstruction if managed with timely nail exchange. Level of Evidence: Level III. See Instructions for Authors for a complete description of levels of evidence.

Identifiers

PMID41869489
PMCPMC13004228

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.