ArticleAmerican journal of nuclear medicine and molecular imaging2026
Scatter correction for self-collimating SPECT using a 3D U-Net framework.
Article in American journal of nuclear medicine and molecular imaging, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Conventional single-photon emission computed tomography (SPECT) relies on mechanical collimators, which impose an inherent trade-off between spatial resolution and sensitivity. A novel cardiac SPECT system that employs a self-collimating design with interleaved mosaic scintillators has been proposed, which markedly enhances sensitivity without compromising resolution. However, the unique self-collimating and closely arranged detector geometry also introduces more complex scatter distribution and increased scatter fractions, making accurate scatter correction essential yet technically challenging. We employed a 3D U-Net framework to directly predict scatter-corrected images from uncorrected images. The network was trained using 36 distinct XCAT phantoms based on GATE simulations, with the true scatter-corrected images (true-SC) precisely obtained from the simulations serving as labels. Quantitative evaluation was performed using another two XCAT phantoms with different contrast levels: a high-contrast phantom (H-Phantom, 10 realizations) and a low-contrast phantom (L-Phantom, 5 realizations). The proposed U-Net approach were compared with two triple energy window (TEW) methods (trapezoidal and triangular). For both contrast levels, the U-Net-based approach achieved higher contrast recovery coefficients, myocardium-to-blood-pool ratios closer to the true-SC, higher contrast-to-noise ratios, and lower relative noise compared to the TEW methods. In addition, the U-Net-based method produced images with higher structural similarity and lower normalized mean square error relative to the true-SC reference, compared with the TEW-corrected images. In conclusion, the proposed 3D U-Net-based scatter correction method provides more accurate scatter estimation and superior quantitative performance for self-collimating SPECT systems than conventional TEW approaches.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.