Evidence map›Paper›PMID 41868354›Full record

ArticleIEEE transactions on radiation and plasma medical sciences2026

ZS4D: Zero-Shot Self-Similarity-Steered Denoiser for Volumetric Photon-Counting CT.

Yongyi Shi, Chuang Niu, Wenjun Xia, Yuxuan Liang, Lin Fu, Bruno De Man, Ge Wang

Abstract read
In one paragraph

Article in IEEE transactions on radiation and plasma medical sciences, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yongyi ShiDepartment of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180 USA.
Chuang NiuDepartment of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180 USA.
Wenjun XiaDepartment of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180 USA.
Yuxuan LiangDepartment of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180 USA.
Lin FuGE HealthCare Technology & Innovation Center (HTIC), Niskayuna, NY, USA.
Bruno De ManGE HealthCare Technology & Innovation Center (HTIC), Niskayuna, NY, USA.
Ge WangBiomedical Imaging Center, Rensselaer Polytechnic Institute, Troy, NY 12180. and Department of Radiology, Wake Forest University, Winston-Salem, SC 27109 USA.

Funding

Cardiac CT DebloomingR01HL151561 · NHLBI · GENERAL ELECTRIC GLOBAL RESEARCH CTR · PI BUDOFF, MATTHEW J, DE MAN, BRUNO · 2020 to 2023
$3.8M
NHLBI NIH HHS R01 HL151561
6 · The paper itself

Abstract

Photon-counting computed tomography (PCCT) has emerged as a transformative imaging modality, enabling enhanced spatial resolution, and multi-energy acquisition with energy-discriminating detectors of significantly smaller detector elements. However, both energy discriminating power and reduced detector pixel size result in fewer detected photons per measurement, inherently increasing noise in reconstructed images. In this study, we propose ZS4D, a zero-shot self-similarity-steered denoiser for PCCT reconstruction. Specifically, a self-similarity denoiser is pre-trained in a self-supervised manner by leveraging spectral correlations through multi-energy extraction and capturing volumetric context via the complementary synergy of axial and sagittal planes. The pre-trained denoiser is then integrated as a prior into an iterative reconstruction framework, enabling effective noise suppression and structural preservation. Extensive experiments demonstrate that ZS4D adapts well to varying noise levels and significantly enhances image quality in both simulated and pre-clinical PCCT datasets. Also, ZS4D demonstrates effectiveness in deblurring tasks. Furthermore, our denoiser pretrained on clinical PCCT data is shown to enhance the spatial resolution of conventional CT images.

Indexed as

denoising and deblurringself-similarityvolumetric photon-counting CTZero-shot

Identifiers

PMID41868354
PMCPMC13004115

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.