Evidence map›Paper›PMID 41866347›Full record

ArticleScientific reports2026

CFD and site analysis for optimizing indoor air quality in sustainable social housing via windcatcher integration.

Mohamed Ibrahim Abdelhady, Mohamed I A Habba, Mohamed Abdelfadel Alsaber, Asmaa Abd Elmoneim Fahmi

Abstract read
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Mohamed Ibrahim AbdelhadyCivil and Architectural Constructions Department, Faculty of Technology and Education, Suez University, P. O. Box: 43221, Suez, Egypt. mohamed.abdelhady@ind.suezuni.edu.eg.
Mohamed I A HabbaMechanical Department, Faculty of Technology and Education, Suez University, P.O.Box: 43221, Suez, Egypt. mohamed.ibrahim@suezuni.edu.eg.
Mohamed Abdelfadel AlsaberCivil and Architectural Constructions Department, Faculty of Technology and Education, Suez University, P. O. Box: 43221, Suez, Egypt.
Asmaa Abd Elmoneim FahmiCivil and Architectural Constructions Department, Faculty of Technology and Education, Suez University, P. O. Box: 43221, Suez, Egypt.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study investigated the potential of integrating windcatchers into Egyptian social housing buildings to enhance natural ventilation and improve indoor thermal comfort, thereby reducing energy consumption used to enhance airflow inside residential spaces of residential communities, which is considered an important aspect of sustainable urban development that aims to counteract climate change. Computational Fluid Dynamics (CFD) simulations validated by site measurements were conducted on two distinctly oriented apartment models. The northwest-oriented apartment demonstrated a 7% improvement in natural ventilation rate with a single strategically placed windcatcher in the bedroom. The southwest-oriented apartment showed a remarkable 45.7% improvement when equipped with three windcatchers distributed across the living room and bedroom spaces. The results revealed that strategic windcatcher placement was more critical than quantity, with a dual-windcatcher configuration in the southwest-oriented apartment achieving a performance nearly comparable to that of a triple-windcatcher arrangement. Effectiveness relies on establishing appropriate pressure gradients through careful positioning to facilitate consistent airflow circulation. Configurations that enhance living room ventilation, the primary family gathering space, demonstrated the greatest potential for improving overall thermal comfort. Practical recommendations include orientation-specific design strategies, early integration of windcatchers into the architectural design process, and standardization of building codes for social housing projects. The implementation of passive cooling strategies offers multiple benefits, including reduced reliance on mechanical cooling, improved indoor air quality, connection to architectural heritage, and significant cumulative energy savings at scale. Future research directions encompass seasonal performance studies, combinations with other cooling strategies, and detailed analyses of windcatcher geometry.

Indexed as

Air Pollution, IndoorHousingHydrodynamicsVentilationComputer SimulationEgyptHumansThermal ComfortCFD simulationEgyptian social housingNatural ventilationSustainabilityWindcatcher

Identifiers

PMID41866347
PMCPMC13009246

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.