Evidence map›Paper›PMID 41862939›Full record

ArticleBMC chemistry2026

Halloysite nanotube-grafted reduced graphene oxide for sensitive electrochemical sensing of niclosamide in food, environmental and biological matrices.

Kunping Guan, Junhong Zhen, Fangfang Lin, Yaqing Wen, Fengyuan Xie, Qingfang Niu, Wei Liu, Lingjie Hou, Yu Huang, Wenting Liang

Abstract read
In one paragraph

Article in BMC chemistry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Kunping Guan *Department of Laboratory Medicine, The Second Hospital of Shanxi Medical University, Taiyuan, 030001, China. guankunping5135@126.com.
Junhong Zhen *Department of Laboratory Medicine, The Second Hospital of Shanxi Medical University, Taiyuan, 030001, China.
Fangfang LinDepartment of Laboratory Medicine, The Second Hospital of Shanxi Medical University, Taiyuan, 030001, China.
Yaqing WenDepartment of Laboratory Medicine, The Second Hospital of Shanxi Medical University, Taiyuan, 030001, China.
Fengyuan XieInstitute of Environmental Science, Shanxi University, Taiyuan, 030006, China.
Qingfang NiuInstitute of Environmental Science, Shanxi University, Taiyuan, 030006, China.
Wei LiuDepartment of Laboratory Medicine, The Second Hospital of Shanxi Medical University, Taiyuan, 030001, China.
Lingjie HouCollege of Chemistry and Materials, Taiyuan Normal University, Jinzhong, 030619, China.
Yu HuangDepartment of Laboratory Medicine, The Second Hospital of Shanxi Medical University, Taiyuan, 030001, China. 201913301001@email.sxu.edu.cn.
Wenting LiangInstitute of Environmental Science, Shanxi University, Taiyuan, 030006, China. liangwt@sxu.edu.cn.

Funding

Basic Research Project of Shanxi Province No. 202203021212190Basic Research Project of Shanxi Province No.20253021212356Funds of Central Government-guided Local Scientific and Technological Development No. YDZJSX2024D005National Natural Science Foundation of China No. 21976113Research Project of the Health Commission of Shanxi Province No. 2025QM015
6 · The paper itself

Abstract

Niclosamide (NA) is widely used as an insecticide in agriculture and fisheries; however, its excessive application poses potential risks to food security and aquatic ecosystems. In this study, halloysite nanotubes (HNTs) were immobilized onto reduced graphene oxide (rGO) via a facile strategy to construct the HNTs-rGO nanocomposite. The introduction of HNTs effectively suppresses the interlayer buildup of rGO, which facilitates efficient interfacial electron transfer and exposes more accessible electroactive sites for NA. Under optimized conditions, this sensor has a wide detection range (0.2-40 µM) for NA with a low limit of detection (LOD) of 66.67 nM. In addition, the sensor exhibits excellent selectivity, reproducibility, and stability. Moreover, the development sensor achieved satisfactory recoveries (96%~103.3%) for NA in pill, water, cucumber, soil and field snail. All strategies proposed HNTs-rGO nanocomposite as a sustainable electrocatalyst that could be explored as an excellent candidate for detecting the NA in real sample analysis.

Indexed as

Electrochemical detectionHalloysite nanotubesNiclosamideReduced graphene oxide

Identifiers

PMID41862939
PMCPMC13127003

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.