Evidence map›Paper›PMID 41862857›Full record

ArticleBMC musculoskeletal disorders2026

Intra- and inter-rater reliability of goniometric head posture measurement in patients with neck pain and hamstring tightness.

Aftab Ahmed Mirza Baig, Basit Ansari, Faizan Siddiqui, Syed Imran Ahmed, Rabia Hassan

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Aftab Ahmed Mirza BaigDepartment of Allied Health Sciences, Faculty of Health Sciences, Iqra University, North Campus, Karachi, Pakistan. dr.aftab@iqra.edu.pk.
Basit AnsariDepartment of Health, Physical Education and Sports Sciences, University of Karachi, Karachi, Pakistan.
Faizan SiddiquiSindh Institute of Physical Medicine and Rehabilitation, Karachi, Pakistan.
Syed Imran AhmedSindh Institute of Physical Medicine and Rehabilitation, Karachi, Pakistan.
Rabia HassanZiauddin College of Physical Therapy, Faculty of Allied Health Sciences, Ziauddin University, Karachi, Pakistan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundNeck pain (NP) is a common disabling condition, often associated with forward head posture (FHP) and hamstring tightness. There is limitation in evidence regarding the intrarater and interrater reliability of FHP evaluation through the universal goniometer (UG) in NP with hamstring tightness. This study aimed to evaluate the intrarater and interrater reliability of the goniometric method for measuring head posture in patients having NP and hamstring tightness.

methodsThis intrarater and inter-rater reliability (between and within-day, respectively) study was conducted on 61 participants having the NP with hamstring tightness at Sindh Institute of Physical Medicine and Rehabilitation, Karachi, Pakistan. Two independent examiners, 1 and 2, measured the FHP using universal goniometer (UG). The measurements were performed by both examiners on day 1. Examiner 1 repeated the measurements after an interval of 2 days. Both examiners were blinded to each other’s readings. Intrarater and interrater reliability were assessed using the Intraclass Correlation Coefficient (ICC) and the Bland-Altman plot.

resultsThere was high intrarater reliability with an ICC of 0.96 (95% CI: 0.92, 0.97; SEM: 0.09 and MCD: 0.24), and interrater reliability with an ICC of 0.97 (95% CI: 0.94–0.98; SEM: 0.10 and MCD: 0.27) of the UG in patients with NP with hamstring tightness. Moreover, both the intrarater and interrater agreements for measuring the FHP using a UG fell to the acceptable limits of agreements on 95% CI. The upper and lower limits of agreement values are 1.06 to -1.58 degrees and 1.05 to -1.75 degrees for the intrarater and interrater reliability, respectively.

conclusionFrom the findings of the study, it is concluded that the UG provides excellent intrarater and interrater reliability to measure FHP among patients having NP with hamstring tightness.

Indexed as

Arthrometry, ArticularHamstring MusclesHeadMuscle TonusNeck PainPostureAdultFemaleHumansMaleMiddle AgedObserver VariationReproducibility of ResultsYoung AdultCervical PainCervical vertebraeMuscle tightnessMusculoskeletal painPostureReproducibility of results

Identifiers

PMID41862857
PMCPMC13126816

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.