ArticleAnnals of biomedical engineering2026
Impact of the Design of Aortic Bioprostheses on Valve Function: A Parametric Study.
Article in Annals of biomedical engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeStructural valve deterioration of aortic bioprosthetic heart valves (BHV) is influenced by leaflet mechanical stress, dependent on design parameters. This study provides a mathematical description of BHV geometry based on these geometric parameters and investigates their influence on valve function.
methodsTen BHV models with variations in geometric parameters were tested under controlled conditions in a cardiac simulator. The Trifecta valve TF-25 (Abbott) was used as a reference geometry to define the "normal" mathematical valve design and was also experimentally tested. The valves were made of silicone using 3D-printed molds. Hemodynamic performance was assessed by Doppler echocardiography. Leaflet motion and strain fields were analyzed with stereophotogrammetry and digital image correlation.
resultsThere was no significant difference in hemodynamic performance between the Trifecta valve and the "normal" silicone valve (p > 0.05). Increased leaflet thickness, smaller diameters, and greater belly curvature reduced significantly (p < 0.01) the hemodynamic performance, while taller leaflets and greater free-edge angle relative to the commissural plane improved the valve performance. Strains during diastole were highest near the commissures. Increased leaflet thickness reduced leaflets deformation, whereas smaller diameters resulted in localized deformation peaks. A greater free-edge angle minimized deformation and increased spacing between leaflets caused inward pulling near stent posts. Excess leaflet height promoted leaflet pinwheeling.
conclusionThe in vitro analysis reveals the differences between various geometries, emphasizing the importance of valve design for BHV function and durability. The development of new BHVs could be improved through in vitro testing. Furthermore, these in vitro experiments can be replicated to evaluate the geometry of native valves.
Indexed as
Identifiers
41862671What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.