Evidence map›Paper›PMID 41862671›Full record

ArticleAnnals of biomedical engineering2026

Impact of the Design of Aortic Bioprostheses on Valve Function: A Parametric Study.

Nicolas Bueno, Viktória Stanová, Julien Favier, Philippe Pibarot

Abstract read
PubMed Publisher
In one paragraph

Article in Annals of biomedical engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Nicolas BuenoInstitut Universitaire de Cardiologie et de Pneumologie de Québec - Université Laval, Québec, Canada.ORCID http://orcid.org/0009-0003-9791-1248
Viktória StanováInstitut Universitaire de Cardiologie et de Pneumologie de Québec - Université Laval, Québec, Canada. viktoria.stanova@criucpq.ulaval.ca.ORCID http://orcid.org/0000-0002-2840-2146
Julien FavierAix Marseille Univ, CNRS, Centrale Med, M2P2, Marseille, France.ORCID http://orcid.org/0000-0002-5397-1324
Philippe PibarotInstitut Universitaire de Cardiologie et de Pneumologie de Québec - Université Laval, Québec, Canada.ORCID http://orcid.org/0000-0002-3607-279X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeStructural valve deterioration of aortic bioprosthetic heart valves (BHV) is influenced by leaflet mechanical stress, dependent on design parameters. This study provides a mathematical description of BHV geometry based on these geometric parameters and investigates their influence on valve function.

methodsTen BHV models with variations in geometric parameters were tested under controlled conditions in a cardiac simulator. The Trifecta valve TF-25 (Abbott) was used as a reference geometry to define the "normal" mathematical valve design and was also experimentally tested. The valves were made of silicone using 3D-printed molds. Hemodynamic performance was assessed by Doppler echocardiography. Leaflet motion and strain fields were analyzed with stereophotogrammetry and digital image correlation.

resultsThere was no significant difference in hemodynamic performance between the Trifecta valve and the "normal" silicone valve (p > 0.05). Increased leaflet thickness, smaller diameters, and greater belly curvature reduced significantly (p < 0.01) the hemodynamic performance, while taller leaflets and greater free-edge angle relative to the commissural plane improved the valve performance. Strains during diastole were highest near the commissures. Increased leaflet thickness reduced leaflets deformation, whereas smaller diameters resulted in localized deformation peaks. A greater free-edge angle minimized deformation and increased spacing between leaflets caused inward pulling near stent posts. Excess leaflet height promoted leaflet pinwheeling.

conclusionThe in vitro analysis reveals the differences between various geometries, emphasizing the importance of valve design for BHV function and durability. The development of new BHVs could be improved through in vitro testing. Furthermore, these in vitro experiments can be replicated to evaluate the geometry of native valves.

Indexed as

Aortic ValveBioprosthesisHeart Valve ProsthesisModels, CardiovascularProsthesis DesignHumansAortic valveCardiac simulatorDigital image correlationHemodynamic testingIn vitro

Identifiers

PMID41862671

What OpenQuestion holds

Textmetadata
Read underepoch 390