Evidence map›Paper›PMID 41860026›Full record

ArticleOrthodontics & craniofacial research2026

Comparative Evaluation of Modified Vacuum-Formed Aligners Versus Conventional Micro-Implant Anchorage in Molar Intrusion for Pre-Restorative Orthodontics.

Tiancong Wang, Yuan Zhang, Jun Ji, Xiang Yan

Abstract readComparative Study
In one paragraph

Article in Orthodontics & craniofacial research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Tiancong WangDepartment of Orthodontics, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology, Nanjing University, Nanjing, China.
Yuan ZhangDepartment of Orthodontics, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology, Nanjing University, Nanjing, China.ORCID https://orcid.org/0000-0001-9530-3378
Jun JiDepartment of Orthodontics, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology, Nanjing University, Nanjing, China.
Xiang YanDepartment of Orthodontics, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology, Nanjing University, Nanjing, China.ORCID https://orcid.org/0009-0003-2794-8336

Funding

Key Project supported by Medical Science and Technology Development Foundation, Nanjing Department of Health ZKX24058
6 · The paper itself

Abstract

objectiveThis study aimed to compare the efficacy of modified vacuum-formed aligners (clear aligners with three-dimensional digital design) versus conventional micro-implant anchorage in molar intrusion for pre-restorative orthodontic treatment.

methodsA total of 91 patients requiring pre-restorative orthodontic treatment were enrolled from Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology, Nanjing University between January 2022 and December 2025. All participants exhibited overeruption of antagonist molars due to long-term absence of mandibular first or second molars, resulting in insufficient space for implant restoration and occlusal plane disturbance, thus requiring molar intrusion prior to prosthetic rehabilitation. Patients were divided into two groups: the aligner group (n = 44, treated with digitally designed clear aligners) and the anchorage group (n = 47, treated with traditional micro-implant anchorage).

resultsThe anchorage group achieved significantly greater buccal and palatal intrusion than the aligner group (p < 0.05). Postoperative VAS scores at 24 h and 3 days in the aligner group were lower than those in the anchorage group (p < 0.05). Both groups showed comparable intrusion of buccal, palatal, mesial, and distal cusps (p > 0.05). The aligner group had a shorter treatment duration (p < 0.05). The complication rate in the aligner group was significantly lower than that in the anchorage group (p < 0.05).

conclusionModified vacuum-formed aligners provided better patient comfort, shorter treatment duration, and fewer complications, whereas micro-implant anchorage demonstrated superior efficiency in molar intrusion. Both techniques achieved satisfactory three-dimensional control, and clinical selection should be based on individual patient needs.

Indexed as

Dental ImplantsMolarOrthodontic Anchorage ProceduresOrthodontic Appliance DesignTooth Movement TechniquesAdolescentFemaleHumansMaleTreatment OutcomeVacuumDental Implantsdigital designinvisible appliancemolar elongationorthodontic compression

Identifiers

PMID41860026
PMCPMC13543175

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.