Evidence map›Paper›PMID 41859506›Full record

ArticleO&G open2026

Removal of Mini-Sling Anchor With Magnetic Resonance Imaging-Guided Site Marking With Methylene Blue.

Sabrina Shih, Kate Maturen, Ashley Skeith, Shane Wells, Tom Chenevert, Vikas Gulani, Daniel M Morgan

Abstract readCase Reports
In one paragraph

Article in O&G open, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Sabrina ShihUniversity of Michigan Medical School, Ann Arbor, Michigan; Department of Radiology, Department of Obstetrics and Gynecology, and Department of Radiology, University of Michigan, Ann Arbor, Michigan.
Kate MaturenUniversity of Michigan Medical School, Ann Arbor, Michigan; Department of Radiology, Department of Obstetrics and Gynecology, and Department of Radiology, University of Michigan, Ann Arbor, Michigan.
Ashley SkeithUniversity of Michigan Medical School, Ann Arbor, Michigan; Department of Radiology, Department of Obstetrics and Gynecology, and Department of Radiology, University of Michigan, Ann Arbor, Michigan.
Shane WellsUniversity of Michigan Medical School, Ann Arbor, Michigan; Department of Radiology, Department of Obstetrics and Gynecology, and Department of Radiology, University of Michigan, Ann Arbor, Michigan.
Tom ChenevertUniversity of Michigan Medical School, Ann Arbor, Michigan; Department of Radiology, Department of Obstetrics and Gynecology, and Department of Radiology, University of Michigan, Ann Arbor, Michigan.
Vikas GulaniUniversity of Michigan Medical School, Ann Arbor, Michigan; Department of Radiology, Department of Obstetrics and Gynecology, and Department of Radiology, University of Michigan, Ann Arbor, Michigan.
Daniel M MorganUniversity of Michigan Medical School, Ann Arbor, Michigan; Department of Radiology, Department of Obstetrics and Gynecology, and Department of Radiology, University of Michigan, Ann Arbor, Michigan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSingle-incision midurethral slings are an alternative to standard midurethral slings for the treatment of stress urinary incontinence. Single-incision midurethral slings use less mesh, relying on soft tissue anchors for mesh stabilization, but can be associated with chronic pain. CASE: We describe the novel use of magnetic resonance imaging to localize and stain a retained radiolucent single-incision midurethral sling anchor with methylene blue dye. This assisted the transvaginal dissection for removal of the stained anchor for a patient with persistent chronic pelvic pain after a prior mesh removal.

conclusionMarking the target anchor with dye provided crucial intraoperative guidance for the surgical dissection. This technique can be a valuable tool for localizing surgical targets that are radiolucent.

Identifiers

PMID41859506
PMCPMC12999148

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked