Evidence map›Paper›PMID 41858983›Full record

ArticleClinical ophthalmology (Auckland, N.Z.)2026

Precision in Intraocular Lens Calculation for Chinese Cataract Patients with Prior History of Radial Keratotomy.

Yang Xiang, Liangpin Li, Haiqiang Yu, Liyun Yuan, Maoyu Cai, Liwei Zhang, Xia Hua, Xiaoyong Yuan

Abstract read
In one paragraph

Article in Clinical ophthalmology (Auckland, N.Z.), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yang XiangClinical College of Ophthalmology, Tianjin Medical University, Tianjin, People's Republic of China.ORCID 0009-0003-3311-7598
Liangpin LiTianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin Eye Institute, Tianjin Eye Hospital, Tianjin, People's Republic of China.
Haiqiang YuClinical College of Ophthalmology, Tianjin Medical University, Tianjin, People's Republic of China.
Liyun YuanTianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin Eye Institute, Tianjin Eye Hospital, Tianjin, People's Republic of China.
Maoyu CaiDepartment of Ophthalmology, The Affiliated Hospital of Guizhou Medical University, Guiyang, People's Republic of China.
Liwei ZhangAffiliated Hospital of Yunnan University, The Second Hospital of Yunnan Province, Yunnan Eye Hospital, Kunming, People's Republic of China.
Xia Hua *Tianjin Aier Eye Hospital, Tianjin University, Tianjin, People's Republic of China.
Xiaoyong Yuan *Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, People's Republic of China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To evaluate the predictive accuracy of eight traditional and contemporary intraocular lens (IOL) power calculation formulas in Chinese cataract patients with prior radial keratotomy (RK). Patients and Methods: RK patients who underwent phacoemulsification with IOL implantation were retrospectively recruited. Refractive prediction errors (RPE)were calculated for eight formulas: Haigis-L, Shammas, Barrett True-K, Camellin Calossi Camellin (CCC), Kane, EVO, Pearl-DGS, and Jin-AI. The study compared RPE, mean absolute error (MAE), median absolute error (MedAE), and percentages of eyes achieving prediction errors within ±0.25, ±0.50, ±0.75, ±1.0, and ±2.0 diopters. Results: This retrospective study analyzed 34 eyes from 21 patients with prior RK surgery. The superior performing IOL power calculation formulas were Jin-AI (MAE = 0.64 D, MedAE = 0.49 D), Barrett True-K (MAE = 0.58 D, MedAE = 0.535 D), and EVO (MAE=0.59 D, MedAE = 0.538 D). These three formulas demonstrated comparable accuracy, with 47.1%, 44.1%, and 44.1% of eyes achieving prediction errors within ±0.50 D, respectively. The Haigis-L and Pearl-DGS formulas exhibited significantly higher prediction errors in eyes with more than 12 RK incisions. Conclusion: The Jin-AI, Barrett True-K, and EVO formulas demonstrated superior accuracy for IOL power calculation in Chinese cataract patients with prior RK. The Jin-AI formula, a novel artificial intelligence-based formula derived from Chinese individuals, presents a promising option for post-RK IOL calculation, while external validation studies across diverse ethnic groups are essential.

Indexed as

cataractIOL power calculationradial keratotomyrefractive prediction errors

Identifiers

PMID41858983
PMCPMC12998632

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.