ArticleClinical ophthalmology (Auckland, N.Z.)2026
Analysis of Ocular Biometric Differences Between Two Optical Biometers in High Myopia Cataract Patients: A Prospective Study.
Article in Clinical ophthalmology (Auckland, N.Z.), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: To compare the differences and consistency of Lenstar LS 900 and IOL Master 700 in measuring ocular biometry for cataract patients with high myopia. Patients and Methods: In this prospective study, 48 cataract patients (67 eyes) with high myopia were included. Paired comparisons were performed for axial length (AL), anterior chamber depth (ACD), lens thickness (LT), keratometry (K1, K2), corneal astigmatism (AST), and white-to-white distance (WTW) in IOL Master 700 and Lenstar LS 900. Agreement between devices was evaluated using Bland-Altman plots, and AL-based subgroup analysis was conducted using measurements from the IOL Master 700. Results: Among the 67 eyes, AL measurement failed in 6 eyes with Lenstar LS 900 but in none with IOL Master 700. Mean inter-device differences were as follows: AL: 0.07 ± 0.11 mm (p = 0.001); ACD: -0.02 ± 0.16 mm (p = 0.351); LT: -0.02 ± 0.28 mm (p = 0.534); K1: -0.03 ± 0.50 D (p = 0.658); K2: -0.04 ± 0.47 D (p = 0.492); AST: -0.03 ± 0.35 D (p = 0.492); WTW: -0.13 ± 0.43 mm (p = 0.017). Two devices were highly correlated for AL, ACD, LT, K1, K2 and AST (ICC > 0.75). Bland-Altman analysis indicated high agreement, with 95% of differences within limits of agreement. No statistically significant difference was found in absolute IOL power prediction between devices. Conclusion: In highly myopic cataract patients, IOL Master 700 shows a higher AL acquisition rate than Lenstar LS 900. Despite statistically significant differences in AL and WTW, no clinically relevant effect on refractive prediction was observed.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.