Evidence map›Paper›PMID 41857342›Full record

ArticleInternational journal of computer assisted radiology and surgery2026

Enhancing automated fracture detection in paediatric wrist X-rays with paired and unpaired cast suppression methods.

Stanley A Norris, Daniel Carrion, Franko Hržić, John R Zech, Sergio Uribe, Mohamed K Badawy

Abstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Stanley A NorrisMonash Radiology, Monash Health, Melbourne, Australia. stanley.norris@monashhealth.org.ORCID http://orcid.org/0009-0001-2801-5074
Daniel CarrionMonash Radiology, Monash Health, Melbourne, Australia.
Franko HržićCentre for Artificial Intelligence and Cybersecurity, Faculty of Engineering, University of Rijeka, Rijeka, Croatia.
John R ZechDepartment of Radiology, Columbia University Irving Medical Center, New York, USA.
Sergio UribeDepartment of Medical Imaging and Radiation Sciences, School of Primary and Allied Health Care, Faculty of Medicine, Nursing and Health Sciences, Monash University, Melbourne, Australia.ORCID http://orcid.org/0000-0002-4970-9710
Mohamed K BadawyMonash Radiology, Monash Health, Melbourne, Australia.ORCID http://orcid.org/0000-0001-8029-9951

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeCasts in follow-up wrist X-rays reduce diagnostic image quality, complicating the assessment of fracture healing. This study developed cast suppression models using real unpaired data and synthetic paired data and investigated their impact on automated fracture detection performance in paediatric wrist X-rays.

methodsA cast suppression model was developed using data generated with unpaired image-to-image translation methods. A published CycleGAN model was repurposed to generate a synthetic paired dataset from an institutional collection of 31,001 X-rays. This dataset was used to train Pix2Pix cast suppression models, using three architectures-U-Net 256, 512, and 1024. Models were evaluated using structural similarity index measure (SSIM), mean-squared error (MSE), and peak signal-to-noise ratio (PSNR). A fracture detection model was trained on a publicly available dataset of 20,327 paediatric wrist X-rays. This model was used to evaluate CycleGAN and Pix2Pix-based cast suppression by testing performance across training sets with varying cast prevalence, defined as 100, 50, 25, and 0% of the naturally occurring cast proportion in the training dataset.

resultsWithin Pix2Pix models, the U-Net 1024 configuration performed best across all metrics (SSIM = 0.957, MSE = 22.2, PSNR = 34.7 dB) and was selected for subsequent fracture detection experiments. Cast suppression improved fracture detection only in models trained without any cast exposure, where Pix2Pix preprocessing increased mAP@0.5 by 4%, from 0.823 (0.008) to 0.859 (0.004), but reduced mAP@0.5 by 1-2% and mAP@0.5:0.95 by 3-4% in models that included cast images during training. Pix2Pix consistently outperformed CycleGAN-based cast suppression across both evaluation metrics (mAP@0.5 and mAP@0.5:0.95), with comparisons assessed using bootstrap resampling.

conclusionThe Pix2Pix model outperformed CycleGAN-based cast suppression for fracture detection preprocessing. However, cast suppression only improved performance in models trained without cast images and reduced performance otherwise. These findings indicate that cast suppression effectiveness depends critically on the downstream model's training data composition.

Indexed as

Casts, SurgicalRadiographic Image Interpretation, Computer-AssistedWrist FracturesAlgorithmsChildHumansArtificial intelligenceCast suppressionFracture detectionGenerative adversarial networks (GANs)Wrist X-rays

Identifiers

PMID41857342
PMCPMC13585798

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.