Evidence map›Paper›PMID 41856588›Full record

ArticleBMJ open2026

Measurement of heart rate and respiratory rate using remote photoplethysmography in paediatrics: a prospective comparative trial protocol - 'rMonitoped1'.

Sébastien Haas-Ferrua, Hugo Giaccardi, Barbara Ancey, Emma Freyssinet, Emma Baranton, Aline Joulie, Imad Bendimerad, Marco Olla, Fabrice De Oliveira, Abdelhak Moussaoui and 3 more

Registry-linked trialAbstract readComparative Study
In one paragraph

Article in BMJ open, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06231654 (Use of Remote Photoplethysmography to Measure Heart Rate and Respiratory Rate in Pediatrics Compared to Standard Acquisition System), which is not on this map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06231654 narecruitingnot on this map

Use of Remote Photoplethysmography to Measure Heart Rate and Respiratory Rate in Pediatrics Compared to Standard Acquisition System: Prospective Comparative Trial

TypeinterventionalSponsorFondation LenvalRan2025 to 2026Enrolled600ConditionsUsing Remote Photoplethysmography for Physiological ParametersArmsRemote photoplethysmography for physiological parameters
3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Sébastien Haas-FerruaPaediatric Emergency Department, Hôpitaux Pédiatriques de Nice CHU-LENVAL, Nice, France.
Hugo GiaccardiPaediatric Emergency Department, Hôpitaux Pédiatriques de Nice CHU-LENVAL, Nice, France.
Barbara AnceyPaediatric Emergency Department, Hôpitaux Pédiatriques de Nice CHU-LENVAL, Nice, France.
Emma FreyssinetPaediatric Emergency Department, Hôpitaux Pédiatriques de Nice CHU-LENVAL, Nice, France.
Emma BarantonPaediatric Emergency Department, Hôpitaux Pédiatriques de Nice CHU-LENVAL, Nice, France.
Aline JoulieDélégation à la Recherche Clinique et à l'Innovation, Centre Hospitalier Universitaire de Nice, Nice, France.
Imad Bendimeradi-Virtual SAS, Metz, France.
Marco OllaPaediatric Emergency Department, Hôpitaux Pédiatriques de Nice CHU-LENVAL, Nice, France.
Fabrice De Oliveirai-Virtual SAS, Metz, France.
Abdelhak Moussaouii-Virtual SAS, Metz, France.
Laurent BoyerEA 3279, "Santé Publique, Maladies Chroniques et Qualité de Vie", Aix Marseille Université, Marseille, France.
Eric FontasDélégation à la Recherche Clinique et à l'Innovation, Centre Hospitalier Universitaire de Nice, Nice, France.
Antoine TranPaediatric Emergency Department, Hôpitaux Pédiatriques de Nice CHU-LENVAL, Nice, France antoine.tran@hpu.lenval.com.ORCID http://orcid.org/0000-0002-1836-2742

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionVital signs such as heart rate (HR) and respiratory rate (RR), crucial for clinical assessment, are often challenging to measure in paediatric populations. Remote photoplethysmography (rPPG), a video-based measurement tool, has demonstrated accuracy in adults. The objective of this study is to compare HR and RR measurements obtained using rPPG with those from standard clinical monitoring in a paediatric population. METHODS AND ANALYSIS: This is a monocentric, prospective study enrolling 600 paediatric participants. Each participant will have standard monitoring electrodes (ECG/impedance) placed on the chest while seated facing a camera for rPPG recording. Simultaneous HR and RR measurements will be recorded over periods of 30 and 60 s using both the standard monitor and the rPPG device. The intraclass correlation coefficient will be calculated to assess agreement between the rPPG and standard monitor measurements. ETHICS AND DISSEMINATION: The study protocol has been approved by the French Agency for the Safety of Health Products (ANSM (Agence nationale de sécurité du médicament) registration no. IDRCB 2023-A02524-41) and by a French ethics committee (CPP Sud Méditerranée III at 29 August 2024, n°2024-A01324-43). The study's findings will be published in peer-reviewed journals and disseminated at national and international conferences and through press releases. TRIAL REGISTRATION NUMBER: Clinical Trials Registry (NCT06231654).

Indexed as

Heart RatePhotoplethysmographyRespiratory RateAdolescentChildChild, PreschoolFemaleFranceHumansInfantMaleProspective StudiesRemote Patient MonitoringResearch DesigneHealthObservational StudyPaediatric intensive & critical careTelemedicineTriage

Identifiers

PMID41856588
PMCPMC13007067

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.