Evidence map›Paper›PMID 41854844›Full record

ArticleMedical physics2026

Revisiting the segmentation threshold for Lu-177 SPECT.

Yibin Liu, Jian Yang, Peng Wang, Yingwei Wang, Yue Chen, Greta S P Mok

Abstract read
In one paragraph

Article in Medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yibin LiuBiomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macau SAR, China.
Jian YangDepartment of Nuclear Medicine, Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan, China.
Peng WangDepartment of Nuclear Medicine, Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan, China.
Yingwei WangDepartment of Nuclear Medicine, Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan, China.
Yue ChenDepartment of Nuclear Medicine, Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan, China.
Greta S P MokBiomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macau SAR, China.

Funding

National Natural Science Foundation of China 82472016National Natural Science Foundation of China 82572278Science and Technology Development Fund of Macau 0016/2023/RIB1
6 · The paper itself

Abstract

backgroundThe mostly used threshold-based segmentation method for SPECT, i.e., 42% of the maximum intensity, was derived from PURPOSE: This study aims to revisit the optimal segmentation threshold for

methodsA cylindrical Jaszczak phantom containing six spheres (2-113 mL) was imaged via simulation and physical experiments using a clinical dual-head NaI SPECT/CT system. The spheres were filled with

resultsThe optimal threshold increased along with the decrease in sphere volume or SBR. For SBR ≥ 3.5:1 and volume ≥ 16 mL, the mean optimal threshold of

conclusionsAn optimal

Indexed as

Image Processing, Computer-AssistedLutetiumRadioisotopesTomography, Emission-Computed, Single-PhotonAlgorithmsHumansPhantoms, ImagingLutetiumLutetium-177Radioisotopes177LuSPECT/CTthresholdtumor segmentation

Identifiers

PMID41854844
PMCPMC13001801

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.