Evidence map›Paper›PMID 41854568›Full record

ArticleJACC. Case reports2026

Aortoplasty and Stent Implantation for the Dacron-Jotec Junction Stenosis: First-in-Human Case Report.

David Garcia-Romero, Alfonso R Mitre, Daniel Molina-Seguil, Francisco Calvo-Iglesias, José Antonio Baz-Alonso, Victor Alfonso Jimenez Diaz

Abstract readCase Reports
In one paragraph

Article in JACC. Case reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

David Garcia-RomeroDepartment of Cardiology, Hospital Álvaro Cunqueiro, University Hospital of Vigo, Vigo, Spain; Department of Cardiology, National Institute of Cardiology Ignacio Chávez, Mexico City, Mexico.
Alfonso R MitreDepartment of Cardiology, Hospital Álvaro Cunqueiro, University Hospital of Vigo, Vigo, Spain.
Daniel Molina-SeguilDepartment of Cardiothoracic Surgery, Hospital Álvaro Cunqueiro, University Hospital of Vigo, Vigo, Spain.
Francisco Calvo-IglesiasDepartment of Cardiology, Hospital Álvaro Cunqueiro, University Hospital of Vigo, Vigo, Spain; Cardiovascular Research Group, Galicia Sur Health Research Institute (IISGS), SERGAS-UVIGO, Vigo, Spain.
José Antonio Baz-AlonsoDepartment of Cardiology, Hospital Álvaro Cunqueiro, University Hospital of Vigo, Vigo, Spain; Cardiovascular Research Group, Galicia Sur Health Research Institute (IISGS), SERGAS-UVIGO, Vigo, Spain.
Victor Alfonso Jimenez DiazDepartment of Cardiology, Hospital Álvaro Cunqueiro, University Hospital of Vigo, Vigo, Spain; Cardiovascular Research Group, Galicia Sur Health Research Institute (IISGS), SERGAS-UVIGO, Vigo, Spain. Electronic address: Victor.Alfonso.Jimenez.Diaz@sergas.es.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundEndovascular aortic repair using hybrid prostheses, such as the Jotec E-vita Open Neo prosthesis, is essential for aortic arch pathology. Anastomotic stenosis following this procedure is a rare complication that requires specialized management. CASE SUMMARY: A 42-year-old man presented with symptomatic severe stenosis between the Dacron graft and the E-vita Open Neo prosthesis after Frozen Elephant Trunk repair. Management included balloon aortoplasty followed by implantation of a 45-mm NuMED CP stent using the balloon-assisted tracking technique. The peak-to-peak gradient was reduced from 85 to 8.5 mm Hg. The patient was discharged 5 days later without complications. DISCUSSION: The balloon-expandable CP stent provided effective luminal re-expansion and durable hemodynamic improvement, demonstrating its value as a mechanical solution for complex postsurgical anastomotic stenosis. TAKE-HOME MESSAGES: Aortoplasty with implantation of a noncovered mechanical stent is a feasible and effective endovascular option to treat complex anastomotic stenosis at the Dacron-Jotec junction after hybrid aortic arch repair.

Indexed as

aortacomplicationdissectionhybrid imagingstenosisstent

Identifiers

PMID41854568
PMCPMC13112555

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.