Evidence map›Paper›PMID 41854396›Full record

ArticleRadiology. Cardiothoracic imaging2026

Deep Learning-based Monoenergetic Imaging for Calcified Coronary Stenosis Assessment at Energy-integrating Detector CT.

Shaojie Chang, Emily K Koons, Hao Gong, Jamison E Thorne, Eric E Williamson, Thomas A Foley, Cynthia H McCollough, Shuai Leng

Abstract read
In one paragraph

Article in Radiology. Cardiothoracic imaging, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Shaojie ChangDepartment of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905.ORCID 0000-0003-0550-9650
Emily K KoonsDepartment of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905.
Hao GongDepartment of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905.ORCID 0000-0002-1123-7172
Jamison E ThorneDepartment of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905.ORCID 0000-0003-3993-6423
Eric E WilliamsonDepartment of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905.ORCID 0000-0002-2066-9612
Thomas A FoleyDepartment of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905.ORCID 0000-0003-0347-7931
Cynthia H McColloughDepartment of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905.ORCID 0000-0002-5346-332X
Shuai LengDepartment of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905.ORCID 0000-0002-6453-9481

Funding

Comprehensive characterization of coronary atherosclerotic disease using photon-counting-detector dual-source CT and its impact on patient managementR01EB028590 · NIBIB · MAYO CLINIC ROCHESTER · PI LENG, SHUAI, MCCOLLOUGH, CYNTHIA H · 2020 to 2023
$2.6M
NIBIB NIH HHS R01 EB028590
6 · The paper itself

Abstract

Purpose To develop and evaluate a Deep learnIng-bAsed MONoenergetic imaging at Different energies (DIAMOND) framework for generating virtual monoenergetic images (VMIs) from conventional energy-integrating detector (EID) CT, aiming to reduce blooming artifacts and improve stenosis assessment in coronary CT angiography (CCTA) with heavily calcified plaques. Materials and Methods This study (August 2022-September 2023) used a combination of retrospective and prospective imaging data. DIAMOND was trained using a simplified U-Net architecture on a retrospective dataset of 10 CCTA examinations performed with ultrahigh-resolution (UHR) photon-counting detector (PCD) CT; 70-keV PCD VMIs (energy equivalent to 120-kV single-energy EID CT) served as inputs and 100-keV PCD VMIs as targets. The trained model was then applied to a prospective dataset of participants with heavily calcified plaques who underwent EID CT at 120 kV followed by same-day PCD CT. Percent diameter stenosis (PDS) was quantified for a phantom and participants by using commercial software and compared across EID CT, DIAMOND, and PCD CT using Bland-Altman analysis. Changes in stenosis severity categorization based on PDS were evaluated. Results DIAMOND reduced blooming artifacts and improved lumen visualization, with image quality resembling PCD CT. In 23 participants (mean age, 69 years ± 8 [SD]; 18 male), average PDS decreased from 35.65% (EID CT) to 25.19% (DIAMOND,

Indexed as

Computed Tomography AngiographyCoronary AngiographyCoronary StenosisDeep LearningRadiographic Image Interpretation, Computer-AssistedVascular CalcificationFemaleHumansMaleProspective StudiesRetrospective StudiesAngiographyCoronary ArteriesCoronary Artery StenosisCoronary CT AngiographyCT–Photon CountingDeep LearningEnergy-Integrating Detector CTPhoton-Counting Detector CT

Identifiers

PMID41854396
PMCPMC13004168

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.