ArticleBrain & spine2026
Single-use optical tracking navigation for external ventricular drain placement: Preclinical 3D-Printed and cadaveric evaluation with a systematic review.
Article in Brain & spine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: External ventricular drain (EVD) placement is common in neurosurgery, yet malposition occurs in up to 38% of cases. While technical adjuncts can improve placement accuracy, simpler and more user-friendly solutions are needed. Our novel single-use optical tracking navigation (OTN) device enables real-time image-guided EVD placement. This proof-of-concept study evaluates the accuracy and usability of this device in both 3D-printed and cadaveric head models. Research question: To evaluate the feasibility and accuracy of a single-use OTN system for EVD placement. Material and methods: Three neurosurgeons each performed three OTN-assisted placements in 3D-printed head models (n = 9). An attending neurosurgeon performed two placements in a cadaveric head (n = 2). The primary endpoint was Kakarla grading. Additional outcomes included fluoroscopy-derived tip-to-target distance, placement duration, and user satisfaction (likelihood to recommend (LTR)). Results: All placements were Kakarla grade 1 (total: 11/11, 100%; 95% CI: 0.72-1.00; 3D-printed: 9/9, 95% CI 0.66 -1.00; cadaveric: 2/2, 95% CI: 0.16 - 1.00). Mean fluoroscopy-derived procedural tip-to-target distance was 13.3 ± 6.4 mm in the 3D-printed models and 22.2 ± 3.2 mm in the cadaveric head. Mean procedure time, including registration and calibration, was 12.1 ± 2.1 min. User satisfaction was positive (mean LTR: 7/10). Discussion and conclusion: The OTN device enables accurate, real-time image-guided EVD placement in both bench and cadaveric models, independent of user experience. Main limitations include the small sample size, ex vivo design, and reliance on 2D fluoroscopy for verification. Larger cadaveric series and clinical trials are needed to confirm accuracy and assess clinical utility.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials