Evidence map›Paper›PMID 41853430›Full record

ArticleCureus2026

Comparative Clinical Performance of Multiple-Head Skin Prick Test Devices: A Prospective Evaluation of Pain, Sensitivity, Specificity, and Intradevice Variability.

Marcos Sanchez-Gonzalez, Troy Grogan, Marvin Smollar, Syed A A Rizvi

Abstract read
In one paragraph

Article in Cureus, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Marcos Sanchez-GonzalezHealth Services Administration, Lake Erie College of Osteopathic Medicine, Bradenton, USA.
Troy GroganResearch and Development, MedScience Research Group, West Palm Beach, USA.
Marvin SmollarResearch and Development, MedScience Research Group, West Palm Beach, USA.
Syed A A RizviBiomedical Sciences, Larkin University, Miami, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and objective Multiple-head skin prick test (SPT) devices are essential tools for percutaneous allergy testing; however, significant interdevice variability exists that may affect diagnostic accuracy, clinical performance, and interpretation. Intradevice variability, characterized by inconsistent responses across individual test heads, may lead to false-positive or false-negative results, potentially compromising allergen identification and treatment planning. This prospective study compared four FDA-cleared multiple-head SPT devices with respect to pain perception, histamine sensitivity, glycerin specificity, and intradevice variability to identify clinically meaningful performance differences. Methods Thirty healthy adults participated in this institutional review board-approved study (approval 33-098). Participants were tested with two 10-head devices (AllerTest-10 (MedScience Research Group, Inc., West Palm Beach, FL, USA; distributed by ALK-Abelló, Inc., Port Washington, NY, USA) and Skintestor OMNI (Greer Laboratories, Inc., Lenoir, NC, USA)) and two eight-head devices (AllerTest-8 (MedScience Research Group, Inc.; distributed by ALK-Abelló, Inc.) and Multi-Test II (Lincoln Diagnostics, Inc., Decatur, IL, USA)). Pain was assessed using a Visual Analog Scale (VAS; 0-10). Histamine (1 mg/mL) and glycerin controls were applied to volar forearm surfaces. Sensitivity was defined as a histamine wheal ≥3 mm, and specificity as a glycerin wheal <3 mm. Intradevice variability was expressed as the coefficient of variation (CV) across test heads. Results Pain scores were low across all devices (mean VAS, 0.92-1.77), with no statistically significant differences. Among the 10-head devices, AllerTest-10 demonstrated superior sensitivity (88% vs. 68%; P = 0.002) and significantly lower intradevice variability (median CV, 0.18 vs. 0.72; P = 0.00024) compared with Skintestor OMNI. Among the eight-head devices, AllerTest-8 showed higher sensitivity (96% vs. 88%; P = 0.026) than Multi-Test II. Both AllerTest devices achieved 100% specificity, whereas comparators achieved 97%-98%. AllerTest devices demonstrated consistently low CV values (0.18-0.19), indicating superior test-head uniformity. Conclusions All evaluated devices demonstrated acceptable patient comfort and clinical performance. However, AllerTest devices exhibited superior clinical performance, characterized by higher histamine sensitivity, perfect glycerin specificity, and markedly lower intradevice variability. These findings suggest that device selection may meaningfully affect diagnostic accuracy, with lower intradevice variability reducing the likelihood of physician misinterpretation and improving the reliability of allergen identification.

Indexed as

allergy skin testingdevice comparisonintradevice variabilitymultiple-head applicatorsensitivityskin prick testspecificity

Identifiers

PMID41853430
PMCPMC12994435

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.