Evidence map›Paper›PMID 41851493›Full record

ReviewClinical oral investigations2026

Shallow vestibular depth as a risk indicator for peri-implantitis: a retrospective analysis of 336 implants.

Bülent Ulaştan, Ahmet Dağ, Hatice Ortaç

Abstract readReview
In one paragraph

Review in Clinical oral investigations, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Bülent UlaştanDepartment of Periodontology, Faculty of Dentistry, Dicle University, Diyarbakır, Türkiye. buelent.ulastan@dicle.edu.tr.ORCID http://orcid.org/0009-0004-0459-8318
Ahmet DağDepartment of Periodontology, Faculty of Dentistry, Dicle University, Diyarbakır, Türkiye.ORCID http://orcid.org/0000-0001-9850-0780
Hatice OrtaçDepartment of Biostatistics, Faculty of Medicine, Dicle University, Diyarbakır, Türkiye.ORCID http://orcid.org/0000-0002-1199-1706

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThis retrospective cross-sectional study aimed to evaluate the relationship between vestibular depth (VD) and peri-implant soft tissue parameters, marginal bone loss (MBL), and peri-implant disease status. MATERIALS AND

methodsA total of 336 implants from 65 patients (27 males, 38 females) who had at least one implant restored prosthetically and whose implants had been in function for at least 1 year were examined at the Department of Periodontology, Faculty of Dentistry, Dicle University. Demographic and clinical data (age, gender, smoking, oral hygiene, implant function duration) were recorded. In the clinical evaluation, VD, keratinized mucosa (KM) width and phenotype, and periodontal/peri-implant parameters (modified plaque index (mPI), modified gingival index (mGI), probing pocket depth (PD), bleeding on probing (BOP), gingival recession, and suppuration) were recorded. Implants were divided into two groups based on VD: shallow VD (≤ 4 mm) and adequate VD (> 4 mm). The primary endpoint was the presence (yes/no) of peri-implantitis at the implant level according to clinical and radiographic criteria, reported as prevalence in the study population. Radiographic bone loss was measured on panoramic radiographs. The VD groups were compared using the Mann–Whitney U and χ² tests; within-patient clustering was accounted for using GEE logistic regression.

findingsA total of 336 implants from 65 patients were evaluated. VD ≤ 4 mm was detected in 26.5% of implants, and > 4 mm in 73.5%. According to clinical diagnosis, 39.9% of implants (n = 134) had peri-implant health, 34.5% (n = 116) had peri-implant mucositis, and 25.6% (n = 86) had peri-implantitis. In the shallow VD group, mPI, mGI, BOP, PD, gingival recession, radiographic bone loss, and suppuration were found to be higher than in the adequate VD group in exploratory bivariate analyses (all p < 0.05). In the multivariate GEE analysis, VD ≤ 4 mm was independently associated with peri-implantitis (OR = 2.405; 95% CI: 1.233–4.690; p = 0.010). Additionally, the odds of peri-implantitis were increased in those with implant duration of 5–10 years (OR = 4.026; p = 0.044), and the maxillary anterior region showed a lower likelihood of peri-implantitis compared to the mandibular posterior region (OR = 0.409; p = 0.026).

conclusionShallow VD was associated with gingival recession, MBL, and the presence of peri-implantitis, along with higher plaque accumulation and soft tissue inflammation. The findings suggest that adequate VD, as a component of the peri-implant phenotype, may be associated with the maintenance of peri-implant health. In particular, in shallow vestibules with a KM width < 2 mm and a thin mucosal phenotype, approaches such as vestibuloplasty and/or soft tissue augmentation may be considered in selected cases to support plaque control. CLINICAL SIGNIFICANCE: Our findings suggest that evaluating VD as part of the peri-implant phenotype may help identify conditions that make maintaining hygiene difficult in areas with shallow vestibules and facilitate discussion of mucogingival approach options in selected cases.

Indexed as

Dental ImplantsPeri-ImplantitisAdultAgedAlveolar Bone LossCross-Sectional StudiesDental Plaque IndexFemaleHumansMaleMiddle AgedPeriodontal IndexRetrospective StudiesRisk FactorsDental ImplantsPeri-implantitisPeri-implant phenotypePeri-implant tissuesVestibule depth

Identifiers

PMID41851493
PMCPMC12999642

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.