Evidence map›Paper›PMID 41851238›Full record

ArticleScientific reports2026

Bonding strength and fatigue survival of conventional, additive and subtractive complete dentures.

Jörg Lüchtenborg, Andreas Keßler, Florian Schneider, Gregor Kleinvogel, Anna-Lena Hillebrecht, Kirstin Vach, Benedikt C Spies

Abstract read
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jörg LüchtenborgDepartment of Prosthetic Dentistry, Center for Dental Medicine, Faculty of Medicine, Medical Center - University of Freiburg, University of Freiburg, Hugstetterstr. 55, 79106, Freiburg, Germany. joerg.luechtenborg@uniklinik-freiburg.de.
Andreas KeßlerDepartment of Prosthetic Dentistry, Center for Dental Medicine, Faculty of Medicine, Medical Center - University of Freiburg, University of Freiburg, Hugstetterstr. 55, 79106, Freiburg, Germany.
Florian SchneiderDepartment of Prosthetic Dentistry, Center for Dental Medicine, Faculty of Medicine, Medical Center - University of Freiburg, University of Freiburg, Hugstetterstr. 55, 79106, Freiburg, Germany.
Gregor KleinvogelPrivate Practice, Clara-Zetkin-Straße 16, Beelitz, Germany.
Anna-Lena HillebrechtDepartment of Prosthetic Dentistry, Center for Dental Medicine, Faculty of Medicine, Medical Center - University of Freiburg, University of Freiburg, Hugstetterstr. 55, 79106, Freiburg, Germany.
Kirstin VachDepartment of Prosthetic Dentistry, Center for Dental Medicine, Faculty of Medicine, Medical Center - University of Freiburg, University of Freiburg, Hugstetterstr. 55, 79106, Freiburg, Germany.
Benedikt C SpiesDepartment of Prosthetic Dentistry, Center for Dental Medicine, Faculty of Medicine, Medical Center - University of Freiburg, University of Freiburg, Hugstetterstr. 55, 79106, Freiburg, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study evaluated the bonding strength, fatigue survival, and fracture modes of dentures fabricated through conventional, additive (SLA/DLP), and subtractive CAD/CAM workflows to test their clinical durability after simulated oral ageing. Eight denture base-tooth combinations (n = 8 per group) were produced using either heat-polymerised PMMA, additively manufactured resins (Formlabs Denture Base LP or Voco V-Print Dentbase) or subtractively milled PMMA (Voco CediTec DB). Prefabricated (VITA Vionic) or CAD/CAM-fabricated denture teeth were then bonded. Surface roughness was quantified using laser scanning microscopy and the degree of conversion using Raman spectroscopy. The specimens underwent hydrothermal ageing with dynamic loading (1.2 million cycles at 5 °C/55 °C) followed by quasi-static shear fracture testing and fracture mode analysis. The conventional fabricated cast-on samples achieved the highest mean fracture load both before (445.7 ± 49.2 N) and after aging (411.7 ± 45.7 N) with 100% survival. Additive workflows (SLA/DLP) groups showed cohesive failures pre-aging; however, the DLP workflow demonstrated a 57% strength reduction post-aging (p = 0.0057) and 87.5% survival. Subtractive groups had the lowest survival rates (50–62.5%), significant strength losses (p < 0.05), and predominantly adhesive failures at the tooth-base interface. Ageing significantly affected bond strength in selected additive and subtractive groups (p < 0.05), whereas the conventional cast-on group remained unaffected. Conventional heat-polymerized PMMA bonded to prefabricated teeth remains the benchmark for denture fabrication. Additive CAD/CAM workflows approach similar performance, whereas subtractive methods require further optimization to improve bond stability under hydrothermal fatigue.

Indexed as

Dental BondingDenture, CompleteComputer-Aided DesignHumansMaterials TestingPolymethyl MethacrylateSurface PropertiesPolymethyl Methacrylate3D printingBond strengthCAD/CAMDenture baseDenture teethPMMAShear fractureSubtractive manufacturingThermomechanical aging

Identifiers

PMID41851238
PMCPMC13003014

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.