Evidence map›Paper›PMID 41846620›Full record

ArticleJournal of biomedical optics2026

Color-filter-array-based multispectral photoplethysmography optical sensor and its motion artifact correction algorithm.

Yunfen Wei, Shu Cong, Runchao Yan, Zekai He, Hong Li, Gongming Yu, Mei Zou

Erratum issuedAbstract read
In one paragraph

Article in Journal of biomedical optics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors.

Yunfen WeiKunming University, School of Physical Science and Technology, Kunming, China.ORCID https://orcid.org/0009-0004-0986-948X
Shu CongKunming University, School of Physical Science and Technology, Kunming, China.
Runchao YanKunming University, School of Physical Science and Technology, Kunming, China.
Zekai HeKunming University, School of Physical Science and Technology, Kunming, China.
Hong LiKunming University, School of Physical Science and Technology, Kunming, China.
Gongming YuKunming University, School of Physical Science and Technology, Kunming, China.
Mei ZouKunming University, School of Physical Science and Technology, Kunming, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Significance: The performance of wearable biosensors is highly influenced by motion artifacts (MAs). Aim: We propose a motion artifact removal algorithm using blind source separation-multi-stage least mean square adaptive filtering with multi-wavelength photoplethysmography (PPG) signals to enable accurate physiological parameter estimation in wearable devices. Approach: The algorithm is implemented with a custom-designed PPG sensor that enables synchronized multi-wavelength acquisition via a compact optical design integrated with a color filter array. The algorithm exploits the high correlation of MA components across wavelengths to autonomously generate a noise reference in real time through blind source separation. Furthermore, a frame-level quality assessment mechanism based on power spectral entropy is introduced, which dynamically evaluates the interference level according to the entropy value and intelligently switches between two pre-optimized sets of filter parameters. This allows for dynamic parameter adjustment of the MSLMS filter, thereby effectively tracking and suppressing motion artifacts without the need for external inertial sensors. Results: The performance of the proposed algorithm was evaluated in a study involving 13 subjects performing free-arm swings to simulate daily motion. Experimental results demonstrate that after algorithm processing, the limits of agreement between the estimated heart rate and the electrocardiogram reference values narrowed from [3.09, 26.94] to Conclusions: We present an integrated hardware-algorithm co-design, offering a practical solution for high-precision and robust physiological monitoring in ambulatory settings using wearable devices.

Indexed as

AlgorithmsPhotoplethysmographySignal Processing, Computer-AssistedWearable Electronic DevicesAdultArtifactsColorElectrocardiographyEquipment DesignFemaleHeart RateHumansMaleMotionblind source separationcolor filtermotion artifactmulti-stage least mean square adaptive filterphotoplethysmographyphysiological parameter estimation

Identifiers

PMID41846620
PMCPMC12989444

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.