Evidence map›Paper›PMID 41846498›Full record

ArticleJournal of applied clinical medical physics2026

Isocenter Optimization in WBRT: Concurrent Sparing of Lens and Lacrimal Gland via Anterior Penumbra Sharpening.

Chen Xie, Xuemei Xia, Haowen Pang, Yan Zhang, Lin Li, Simin Lu

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Chen XieDepartment of Oncology, Luzhou People's Hospital, Luzhou, Sichuan, China.ORCID https://orcid.org/0009-0008-8739-9769
Xuemei XiaDepartment of Plastic and Burn Surgery, The Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan, China.
Haowen PangDepartment of Oncology, The Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan, China.ORCID https://orcid.org/0000-0003-4877-9343
Yan ZhangDepartment of Oncology, Luzhou People's Hospital, Luzhou, Sichuan, China.
Lin LiDepartment of Oncology, Luzhou People's Hospital, Luzhou, Sichuan, China.
Simin LuDepartment of Oncology, Luzhou People's Hospital, Luzhou, Sichuan, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWith improving survival for patients receiving whole-brain radiotherapy (WBRT), mitigating long-term toxicities like cataract and dry eye syndrome has become increasingly critical. The lens and lacrimal gland are highly radiosensitive and lie in close proximity to the target volume, posing a persistent challenge for achieving sharp dose gradients. While modern techniques like multileaf collimator (MLC) shaping offer some protection, the potential of classic geometric optimization principles, such as anterior beam shift, remains underexplored in contemporary treatment planning workflows. PURPOSE: This study aimed to systematically translate, quantitatively validate, and integrate the classic geometric principle of anterior isocenter shift into the modern treatment planning workflow for the dual protection of the lens and lacrimal gland in WBRT, utilizing 3D-conformal radiotherapy (3D-CRT) and field-in-field (FIF) techniques.

methodsFor 40 patients, conventional and isocenter-optimized plans (involving an anterior shift of the isocenter within the PTV) were generated for both 3D-CRT and FIF. We compared dosimetric parameters for the planning target volume (PTV), lenses, lacrimal glands, and other organs at risk. Plan quality, normal tissue complication probability (NTCP) for cataract and dry eye syndrome, and clinical risk stratification were evaluated

resultsIsocenter optimization significantly reduced the median lens Dmax by 20% and PRV_lens D0.03 cm3 by 23% (p < 0.001). Lacrimal gland Dmean, V6Gy, and V10Gy were also significantly reduced. The strategy physically improved the dose gradient, narrowing the penumbra width by 31.25% and increasing the dose fall-off rate by 15%, while reducing low-dose irradiation volumes outside the PTV. These dosimetric benefits translated into meaningful reductions in projected NTCP for both complications. The 3D-FIF plans maintained target coverage and homogeneity, mitigating the heterogeneity increase observed in 3D-CRT plans.

conclusionAnterior isocenter optimization is a practical, and hardware-free technique that seamlessly synergizes with modern MLC-based planning to provide significant, concurrent sparing of the lens and lacrimal gland in WBRT. As a readily implementable modification within existing planning systems, this strategy can be adopted immediately to enhance treatment safety without requiring additional resources.

Indexed as

Brain NeoplasmsCranial IrradiationLacrimal ApparatusLens, CrystallineOrgans at RiskOrgan Sparing TreatmentsRadiotherapy Planning, Computer-AssistedHumansPrognosisRadiotherapy, ConformalRadiotherapy DosageRadiotherapy, Intensity-Modulatedfield‐in‐field technique (FIF)isocenter optimizationlacrimal glandlensthree‐dimensional conformal radiotherapy (3D‐CRT)whole‐brain radiotherapy (WBRT)

Identifiers

PMID41846498
PMCPMC13093415

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked