ArticleScientific reports2026
Effect of copper rod length on the melting behavior of paraffin wax in hemispherical latent heat storage units.
Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
The inherently low thermal conductivity of phase change materials (PCMs) stills a major limitation for their use in latent heat thermal energy storage (LHTES) units, as it significantly reduces the charging procedure and decreases system responsiveness. This study presents a novel numerical examination of the isolated effect of a single vertical copper rod of varying lengths on the melting performance of RT42 paraffin wax within a hemispherical cell. Unlike previous studies that focused on fins or composite structures in other geometries, this work uniquely quantifies the impact of systematically increasing rod length (0, 10, 20, and 30 mm) on melting enhancement in hemispherical configurations. Four cases had been simulated using ANSYS Fluent 16 with enthalpy-porosity technique to obtain transient heat transfer, fluid flow, and evolution of melting front. It was shown that the copper rod boosted thermal exchange and shortened the total time of melting, and it took 300 min (no rod) to 150, 120, and 90 min when using 10, 20, and 30 mm copper rod, respectively. The highest reduction in melting time was 70 percent and the corresponding increment in the melting rate was 233 percent in the longest rod compared to the finless. Besides, the existence of the rod resulted in the existence of more homogeneous temperature distributions and stronger convective currents, which increased the overall thermal efficiency. The findings provide valuable design guidance, demonstrating that the thermal conductivity limitation of organic PCMs can be effectively overcome through simple geometric modifications using high-conductivity inserts.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.