Deep learning-based upsampling of 2D detector array measurements for patient plan verification in radiotherapy.
Article in Medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundDetector arrays are commonly used for treatment plan verifications in intensity modulated radiation therapy. However, the intrinsic resolution of detector arrays is limited by the physical dimensions of each single detector and the detector-to-detector distance. This may lead to inaccurate representations of steep gradients and narrow dose peaks. PURPOSE: This work presents a deep learning approach for increasing the effective spatial resolution of detector arrays used for patient plan verification. The presented approach aims to augment missing values in the insensitive areas of the detector matrix and to increase the sampling frequency of the measured 2D dose profile. Furthermore, perturbations caused by finite detector's dimensions via the volume-averaging effect are corrected during the upsampling process.
methodsIn this work, Monte Carlo simulation methods were employed to synthetically generate training data, enabling a wide coverage of different linear accelerator setups and field shapes. The approach was implemented for the OCTAVIUS Detector 1500 (PTW Freiburg, Germany), which consists of 1405 air-filled ionization chambers arranged in a checkerboard pattern. This arrangement enables a threefold increase in resolution from 5 mm, achieved with the standard bilinear interpolation, to 1.7 mm using neural networks. The implemented neural networks are based on a deep convolutional architecture and were trained using PyTorch. Initially, the models were tested by comparing the upsampled measurements of individual step-and-shoot IMRT segments with measurements obtained using a high-resolution OCTAVIUS Detector 1600 SRS liquid-filled ionization chamber array. In addition, radiochromic film measurements of fields with leaf gaps of 1 and 2 cm were used to demonstrate the differences between measurements and interpolation results in the presence of steep gradients and narrow dose peaks. Finally, reconstructed 3D dose distributions of VMAT plans, using both the original and upsampled measurements, were compared to the treatment planning system calculations.
resultsThe comparison of the individual IMRT segments with a standard bilinear interpolation showed an average increase in the gamma index passing rate of up to 20%. In the case of 3D dose reconstructions from the field-by-field IMRT measurements in the OCTAVIUS 4D phantom, the neural network upsampling yielded an average increase in passing rate of 22% as compared to bilinear interpolation, when using the OD 1600SRS array measurements as reference and 19% with the TPS calculated dose distribution as reference. Similarly, for VMAT plans, the passing rate showed an average increase of 8% for the measurement at an Elekta accelerator and 7% at a Varian Ethos accelerator, both using the TPS dose distribution as reference.
conclusionIt has been shown that a neural network can be applied to upsample the detector array resolution. This results in a better interpolation of measurement points, especially in regions of steep gradients, than compared to a standard bilinear interpolation. The passing rates of all investigated VMAT plans are increased by applying the proposed neural network upsampling approach.