ArticlePediatric surgery international2026
Flow efficiency of 3D-printed refeeding tubes in a simulated neonatal high-output stoma model.
Article in Pediatric surgery international, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
purposeNeonatal enterostomies often cause high-output losses of intestinal contents, leading to malabsorption, growth failure, and dependence on parenteral nutrition. Conventional refeeding relies on intermittent or continuous reinfusion and may entail contamination risk and technical difficulties.
methodsThis study introduces an indwelling tube refeeding approach that connects the proximal and distal bowel through a single continuous tube, enabling uninterrupted physiological flow. Using a bench-top in vitro model simulating a neonatal high-output stoma, nine three-dimensional -printed tubes (three diameters × three configurations) were tested at two infusion rates (100 and 50 mL/h).
resultsAll 90 trials achieved continuous distal outflow without occlusion, confirming technical feasibility. Flow efficiency increased with tube diameter: at 100 mL/h, efficiencies were 95.2 ± 5.2% (9 mm), 62.5 ± 12.3% (7 mm), and 55.5 ± 8.6% (5 mm); a similar pattern was observed at 50 mL/h. Tube configuration and infusion rate had minimal effects on flow efficiency.
conclusionThis bench-top study demonstrates the feasibility of an indwelling bridging tube for continuous proximal-to-distal transfer in vitro. Although larger diameters achieved higher flow efficiency, smaller-caliber tubes occupying approximately 40% of the lumen still achieved > 56% efficiency in this model; however, clinical safety and efficacy require further biomechanical and in vivo validation.
Indexed as
Identifiers
41838169What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.