ArticleInternational journal of particle therapy2026
An Artificial Intelligence Dose Engine for Fast Carbon Ion Treatment Planning.
Article in International journal of particle therapy, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Transformer-based rapid dose calculation for carbon ion therapy.Medical physics · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: Monte Carlo (MC) simulations provide gold-standard accuracy for carbon ion therapy dose calculations but are computationally intensive, limiting their use in adaptive workflows. Analytical pencil beam algorithms offer speed but reduced accuracy in heterogeneous tissues. This study develops the first AI-based dose engine capable of predicting relative biological effectiveness-weighted doses. Absorbed dose, α, and β parameters for optimization are calculated at MC-level accuracy with a drastically reduced computational time. Materials and Methods: We extended the transformer-based DoTA architecture to predict absorbed dose (C-DoTA-d), α (C-DoTA-α), and β (C-DoTA-β), introducing a cross-attention mechanism for α and β to combine dose and energy inputs. The training dataset consisted of approximately 70 000 pencil beams from 187 head-and-neck patients, with ground-truth values obtained using the GPU-accelerated MC toolkit FRED. Performance was evaluated on an independent test set using gamma pass rate (1%/1 mm), depth-dose, and isodose contour Dice coefficients. MC dropout-based uncertainty analysis was performed. Results: Median gamma pass rates exceeded 98% for all predictions (99.76% for dose, 99.14% for α, 98.74% for β), with minima above 85% in the most heterogeneous anatomies. The Dice coefficient was 0.95 for 1% isodose contours, with slightly reduced agreement in high-gradient regions. Compared to MC FRED, inference was over 400× faster (0.032 vs 14 seconds per pencil beam) while maintaining accuracy. Uncertainty analysis showed high stability, with mean standard deviations below 0.5% for all models. Conclusions: This AI-based dose engine achieves MC-quality predictions of absorbed dose and relative biological effectiveness model parameters in ∼30 ms per beamlet. Its speed and accuracy support online adaptive planning, paving the way for more effective carbon ion therapy workflows. Future work will expand to additional anatomical sites, beam geometries, and clinical beamlines.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.