Evidence map›Paper›PMID 41833307›Full record

ArticleJournal of the American Association for Laboratory Animal Science : JAALAS2026

Pharmacokinetics and Analgesic Efficacy of a Novel Extended-Release Buprenorphine Formulation in Mice.

Stephanie Yang, Christopher D Fry, Laura B Durham, Daniel D Myers, Patrick A Lester

Abstract read
In one paragraph

Article in Journal of the American Association for Laboratory Animal Science : JAALAS, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Letter to the Editor.Journal of the American Association for Laboratory Animal Science : JAALAS · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Stephanie Yang1Refinement and Enrichment Advancements Laboratory, Unit for Laboratory Animal Medicine, University of Michigan, Ann Arbor, Michigan; and.
Christopher D Fry1Refinement and Enrichment Advancements Laboratory, Unit for Laboratory Animal Medicine, University of Michigan, Ann Arbor, Michigan; and.
Laura B Durham2Conrad Jobst Vascular Research Laboratories, University of Michigan, Ann Arbor, Michigan.
Daniel D Myers1Refinement and Enrichment Advancements Laboratory, Unit for Laboratory Animal Medicine, University of Michigan, Ann Arbor, Michigan; and.
Patrick A Lester1Refinement and Enrichment Advancements Laboratory, Unit for Laboratory Animal Medicine, University of Michigan, Ann Arbor, Michigan; and.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Long-acting buprenorphine formulations present a remarkable refinement for the care and management of postoperative pain in rodents. We describe here the evaluation of a novel extended-release buprenorphine formulation (Bup ER) for use in laboratory mice. The pharmacokinetics of a single subcutaneous dose of Bup ER (5 mg/kg) were characterized in male and female CD-1 mice at 0.5, 2, 4, 8, 24, 48, 72, 96, 120, and 168 hours postinjection. Plasma buprenorphine concentrations exceeded 1 ng/mL within 0.5 hours and were maintained above this threshold for up to 120 hours postadministration. The analgesic efficacy of Bup ER was assessed using a tail flick thermal nociception assay and a plantar incisional hypersensitivity model. Mice received Bup ER (5 mg/kg SC, once) or saline (subcutaneously, once) prior to tail flick nociception testing or plantar incisional surgery with corresponding mechanical (von Frey) and thermal (Hargreaves) hypersensitivity testing. Tail flick thermal nociception testing for male and female CD-1 mice indicated significant differences in maximum possible effect between Bup ER and saline groups from 0.5 to 96 hours. Mechanical hypersensitivity was not observed in male or female Bup ER-treated groups for up to 96 hours. Although thermal hypersensitivity was observed in male and female mice that received Bup ER, mice presented significantly less thermal hypersensitivity (attenuation) compared with the saline group from 1 to 48 hours. No abnormal clinical observations were appreciated. Gross findings revealed mild erythema or alopecia at the injection site, and 3 mice developed skin ulcerations that were attributed to injection technique where use of small-gauge needles led to administration into the intradermal compared with subcutaneous space. Ulcerative lesions were not observed after procedures to confirm injection site administration were implemented. Bup ER provided effective postoperative analgesia for 48-96 hours in mice and demonstrated an extended plasma concentration profile up to 120 hours for long-acting analgesia.

Indexed as

AUC0-inf, AUC extrapolated to infinityBup ER, extended-release buprenorphineMPE, maximum possible efficacyMRT0-inf, MRT extrapolated to infinityMRT, mean residual time

Identifiers

PMID41833307
PMCPMC13249351

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.