Evidence map›Paper›PMID 41830515›Full record

ArticleEpilepsia2026

Arterial spin labeling performs comparably to 2-[

Antonio Giulio Gennari, Dorottya Cserpan, Raimund Kottke, Niklaus Krayenbühl, Michael Messerli, Martin W Hüllner, Ruth O'Gorman Tuura, Georgia Ramantani

Abstract readComparative Study
In one paragraph

Article in Epilepsia, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Antonio Giulio GennariDepartment of Neuropediatrics, University Children's Hospital Zurich, Zurich, Switzerland.ORCID https://orcid.org/0000-0003-2224-0083
Dorottya CserpanDepartment of Neuropediatrics, University Children's Hospital Zurich, Zurich, Switzerland.ORCID https://orcid.org/0000-0002-7538-1931
Raimund KottkeDepartment of Radiology, University Children's Hospital Zurich, Zurich, Switzerland.ORCID https://orcid.org/0000-0003-0166-2770
Niklaus KrayenbühlDivision of Pediatric Neurosurgery, University Children's Hospital Zurich, Zurich, Switzerland.ORCID https://orcid.org/0000-0003-1089-221X
Michael MesserliDepartment of Nuclear Medicine, University Hospital Zurich, Zurich, Switzerland.ORCID https://orcid.org/0000-0001-7815-3048
Martin W HüllnerDepartment of Nuclear Medicine, University Hospital Zurich, Zurich, Switzerland.ORCID https://orcid.org/0000-0002-4849-3292
Ruth O'Gorman TuuraMR-Research Center, University Children's Hospital Zurich, Zurich, Switzerland.ORCID https://orcid.org/0000-0001-5932-7786
Georgia RamantaniDepartment of Neuropediatrics, University Children's Hospital Zurich, Zurich, Switzerland.ORCID https://orcid.org/0000-0002-7931-2327

Funding

Alfred and Annemarie von Sick legacyAnna Mueller Grocholski FoundationCRPP Artificial Intelligence in Oncological Imaging NetworkGE HealthcareNational Science Foundation 208184Theodor und Ida Herzog-Egli-Stiftung
6 · The paper itself

Abstract

objectiveThis study was undertaken to test whether arterial spin labeling (ASL) performs comparably to 2-[

methodsWe retrospectively included children with epilepsy due to focal cortical dysplasia, low-grade epilepsy-associated tumors, or hippocampal sclerosis who underwent standardized magnetic resonance imaging (MRI; including single-delay ASL) and FDG-PET during presurgical evaluation. Lesions, perilesional perfusion, and metabolic abnormalities were segmented and coregistered. Spatial overlap was quantified using DICE scores to compare functional modalities with each other (perfusion-to-metabolism: DICE

resultsFifteen children were included; median ages at FDG-PET and ASL were 7.7 and 7.5 years; 53% required sedation. Median perilesional volumes were 11 339 mm SIGNIFICANCE: ASL yielded perilesional findings equivalent to FDG-PET and showed comparable overlap with the resection cavity in seizure-free children. As a radiation-free technique embedded into routine MRI, ASL reduces logistics and avoids an additional sedation session. These findings support ASL as a practical alternative to FDG-PET for presurgical workup, especially when FDG-PET access is limited.

Indexed as

EpilepsyFluorodeoxyglucose F18Positron-Emission TomographySpin LabelsAdolescentBrain NeoplasmsChildChild, PreschoolFemaleFocal Cortical DysplasiaHippocampal SclerosisHumansMagnetic Resonance ImagingMalePerfusion Magnetic Resonance ImagingRadiopharmaceuticalsFluorodeoxyglucose F18RadiopharmaceuticalsSpin Labelsepilepsy surgeryimagingMRIpediatric focal lesional epilepsyPET

Identifiers

PMID41830515
PMCPMC13285237

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.