Evidence map›Paper›PMID 41829639›Full record

ArticleSensors (Basel, Switzerland)2026

A Single-Cell Optically Pumped Intrinsic Gradiometer.

Nicholaus Zilinski, Ash M Parameswaran, Bonnie L Gray, Teresa Cheung

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Nicholaus ZilinskiSchool of Engineering Science, Simon Fraser University, Burnaby, BC V5A 1S6, Canada.
Ash M ParameswaranSchool of Engineering Science, Simon Fraser University, Burnaby, BC V5A 1S6, Canada.
Bonnie L GraySchool of Engineering Science, Simon Fraser University, Burnaby, BC V5A 1S6, Canada.
Teresa CheungSchool of Engineering Science, Simon Fraser University, Burnaby, BC V5A 1S6, Canada.ORCID 0000-0002-4169-1587

Funding

Natural Sciences and Engineering Research Council of Canada 05837
6 · The paper itself

Abstract

Optically pumped magnetometers (OPMs) provide a non-cryogenic alternative to superconducting quantum interference devices (SQUIDs) for detecting weak biomagnetic fields. We report the design, construction, and characterization of a single-cell intrinsic OPM gradiometer. The gradiometer employs a rubidium-87 vapor cell in an orthogonal pump and probe beam configuration. The pump beam was split to illuminate two parallel sensing regions of the cell, separated by a baseline of 3 cm, with opposing circular polarization. A linearly polarized probe beam propagated through both regions and was captured by a balanced polarimeter whose output directly measured the spatial magnetic gradient. This prototype achieved a common-mode rejection ratio exceeding 50 dB and a sensitivity of 267 pT/cm/√Hz without passive magnetic shielding, using active ambient-field coils. As a proof of concept, we recorded preliminary cardiac-synchronous magnetic measurements using an optical pulse sensor for beat segmentation. After bandpass filtering and ensemble averaging, a cardiac-synchronous waveform was observed, consistent with cardiac timing. Unlike many multi-cell gradiometers that require complex calibration, modulation, and passive shielding, this single-cell design reduces cost and complexity.

Indexed as

biomagnetic sensingcommon-mode rejectionintrinsic gradiometeroptically pumped magnetometer

Identifiers

PMID41829639
PMCPMC12987060

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.