ArticleSensors (Basel, Switzerland)2026
Criterion Validity and Inter-Method Reliability of a Smartphone Sensor-Based Application for Lower-Limb Range of Motion: In-Person vs. Tele-Assessment.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The increasing use of telerehabilitation has intensified the need for validated smartphone sensor-based tools capable of accurately capturing joint range of motion (ROM). This study examined the criterion validity of the PhysioMaster application compared with a universal goniometer during in-person assessments and evaluated the inter-method reliability between in-person and online PhysioMaster measurements. Thirty healthy young adults underwent standardized hip, knee, and ankle ROM testing using both approaches. The criterion validity was limited for most joints, with only ankle plantarflexion demonstrating the highest validity and dorsiflexion showing a moderate association; in contrast, hip and knee ROM exhibited poor agreement with goniometric values. Despite limited absolute agreement, PhysioMaster demonstrated moderate to good inter-method reliability for hip and knee ROM, indicating consistency across assessment modes. These findings suggest that while PhysioMaster may not serve as a direct substitute for in-person goniometry, it shows potential as a consistent tool for tracking ROM changes remotely, particularly for hip and knee movements. The application may support remote musculoskeletal monitoring within telerehabilitation contexts where repeated, standardized assessments are required.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.