Evidence map›Paper›PMID 41829434›Full record

ArticleSensors (Basel, Switzerland)2026

Gaussian-Fitting-Enabled High-Accuracy pH Detection for Light-Addressable Potentiometric Sensor.

Jie Tan, Zigeng Huang, Bin Sun, Xin Cao, Zijie Tang, Guomao Yan, Jiangze Ren, Shibin Liu, Yinghao Chen, Guifang Li and 2 more

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Jie TanSchool of Electrical Engineering and Electronic Information, Xihua University, Chengdu 610097, China.ORCID 0009-0004-3123-3146
Zigeng HuangSchool of Electrical Engineering and Electronic Information, Xihua University, Chengdu 610097, China.
Bin SunSchool of Electrical Engineering and Electronic Information, Xihua University, Chengdu 610097, China.
Xin CaoSchool of Electrical Engineering and Electronic Information, Xihua University, Chengdu 610097, China.
Zijie TangSchool of Electrical Engineering and Electronic Information, Xihua University, Chengdu 610097, China.
Guomao YanSchool of Electrical Engineering and Electronic Information, Xihua University, Chengdu 610097, China.
Jiangze RenSchool of Electrical Engineering and Electronic Information, Xihua University, Chengdu 610097, China.
Shibin LiuSchool of Electronics and Information, Northwestern Polytechnical University, Xi'an 710072, China.
Yinghao ChenSchool of Electronics and Information, Northwestern Polytechnical University, Xi'an 710072, China.
Guifang LiSchool of Electronics and Information, Northwestern Polytechnical University, Xi'an 710072, China.
Xueliang LiSchool of Mechanical and Electrical Engineering, Zhoukou Normal University, Zhoukou 466001, China.
Dong ChenSchool of Electronics Engineering, Xi'an University of Posts and Telecommunications, Xi'an 710121, China.

Funding

National Natural Science Foundation of China 61873209Xihua University Science and Technology Innovation Competition Project for Postgraduate Stu-dents RC2400002117, RC2400002131Xihua University Talent Introduction Program Z242116
6 · The paper itself

Abstract

A light-addressable potentiometric sensor (LAPS) is a low-cost and versatile semiconductor field-effect pH sensor. In practical application, typical pH detection based on LAPS usually adopts the method of normalizing the voltage-photocurrent (V-I) characteristic to solve the working point. However, this method not only needs to obtain the data of the whole V-I characteristic, which leads to slow and time-consuming measurement, but the selection of the working point is also greatly influenced by the shape and noise of the V-I characteristic. In view of this, a new pH measurement method is proposed in this paper, which reduces the impact of noise fluctuations by fitting a Gaussian function to the local depletion region of the V-I characteristic and is almost unaffected by some measurement points distortions of the V-I characteristic, and the measurement results are directly obtained from robust morphological parameters of the fitted function. The experimental results show that the new measurement method can not only obtain pH detection with high sensitivity, high linearity and strong specificity but also further improve the detection speed by shortening the range of the bias voltage, reducing the number of measurement points, and increasing the step value of the bias voltage. At the same time, the measurement method has strong anti-interference ability when the light source fluctuates and is applicable to a variety of waveform excitation scenarios. In practical application, this measurement method has low errors in the pH detection of sewage samples. The measurement method expands the measurement mode of LAPS and provides a new idea for high-precision, rapid pH detection and other biochemical species detection marked by pH.

Indexed as

depletion regionGaussian functionhigh detection performancelight-addressable potentiometric sensorpH detection

Identifiers

PMID41829434
PMCPMC12987349

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.