ArticleSensors (Basel, Switzerland)2026
Continuous Accelerometry-Based Tremor Detection During Daily Living.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
As a step towards advancing adaptive DBS control for Parkinson's disease, we have developed an automated algorithm that detects tremor continuously on a seconds-resolution time scale from a wearable accelerometer and present the feasibility study test results. Triaxial acceleration data were wirelessly streamed from an Apple Watch as well as acquired from an internal accelerometer in the implanted DBS device itself. The algorithm first determines if there is any high-power voluntary activity, such as walking, using the arm, or transitioning from sitting to standing; then, it identifies peaks in the 4-7 Hz Parkinsonian tremor frequency band. Peak detection for tremor activity was more accurate using the Apple Watch than the IPG. Peak and harmonic detection were also more accurate using continuous wavelet transforms than short-time Fourier transform. According to the repeated measures correlation, our detection algorithm correlated strongly with DBS intensity (Subject RZCH: r = -0.93,
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.