Evidence map›Paper›PMID 41829398›Full record

ArticleSensors (Basel, Switzerland)2026

AWG-Based Spectral Multiplexing for Unambiguous Range-Extended FMCW LiDAR.

Sangwon Park, Sang Min Park, Seongmun Jeong, Gyeongmin Kweon, Chang-Seok Kim, Hwidon Lee

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Sangwon ParkDepartment of Optics and Mechatronics Engineering, Pusan National University, Busan 46241, Republic of Korea.ORCID 0009-0000-0325-5680
Sang Min ParkEngineering Research Center for Color-Modulated Extra-Sensory Perception Technology, Pusan National University, Busan 46241, Republic of Korea.
Seongmun JeongDepartment of Optics and Mechatronics Engineering, Pusan National University, Busan 46241, Republic of Korea.ORCID 0009-0004-8278-022X
Gyeongmin KweonDepartment of Cogno-Mechatronics Engineering, Pusan National University, Busan 46241, Republic of Korea.ORCID 0009-0001-5492-225X
Chang-Seok KimEngineering Research Center for Color-Modulated Extra-Sensory Perception Technology, Pusan National University, Busan 46241, Republic of Korea.ORCID 0000-0002-2811-8137
Hwidon LeeEngineering Research Center for Color-Modulated Extra-Sensory Perception Technology, Pusan National University, Busan 46241, Republic of Korea.ORCID 0000-0002-6819-0715

Funding

Korea Planning & Evaluation Institute of Industrial Technology (KEIT) and the Ministry of Trade, Industry & Energy (MOTIE) of the Republic of Korea RS-2025-02622970National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIT) NRF-RS-2021-NR060086
6 · The paper itself

Abstract

Frequency-modulated continuous-wave (FMCW) light detection and ranging (LiDAR) based on coherent ranging is a technology capable of high-resolution distance measurement while remaining robust against ambient light interference. However, extending the measurable range remains challenging due to (i) the coherence length limitation of the laser and (ii) distance ambiguity caused by frequency ambiguity in coherent detection. To overcome these limitations, we propose an unambiguous range-extended FMCW LiDAR enabled by arrayed waveguide grating (AWG)-based spectral multiplexing. By spectrally demultiplexing the reference arm into four wavelength channels with sequentially designed optical path delays, multiple independent interference signals are obtained simultaneously without increasing the number of photodetectors or optical couplers. A channel-pair-based distance decoding algorithm is further introduced to resolve distance ambiguity by classifying detection outcomes across adjacent channels and selectively applying predefined operations. The proposed FMCW LiDAR system effectively extends the measurable range to approximately five times that of a conventional FMCW LiDAR. Experimental results demonstrate high measurement accuracy and successful reconstruction of three-dimensional distance maps, validating the system's potential for extended-range FMCW LiDAR applications.

Indexed as

FMCW LiDARspectral multiplexingunambiguous ranging

Identifiers

PMID41829398
PMCPMC12986739

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.