Evidence map›Paper›PMID 41826581›Full record

ArticleAnnals of biomedical engineering2026

Field Evaluation of a Wearable Instrumented Headband Designed for Measuring Head Kinematics.

Anu Tripathi, Yang Wan, Zhiren Zhu, Furkan Camci, Sheila Turcsanyi, Jeneel Pravin Kachhadiya, Mauricio Araiza Canizales, Alison Brooks, Haneesh Kesari, Joseph Andrews and 4 more

Abstract read
PubMed Publisher
In one paragraph

Article in Annals of biomedical engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Anu TripathiDepartment of Engineering, Robert Morris University, Moon Township, PA, USA.
Yang WanSchool of Engineering, Brown University, Providence, RI, USA.
Zhiren ZhuDepartment of Mechanical Engineering, University of Michigan, Ann Arbor, MI, USA.
Furkan CamciWaisman Center, University of Wisconsin-Madison, Madison, WI, USA.
Sheila TurcsanyiWaisman Center, University of Wisconsin-Madison, Madison, WI, USA.
Jeneel Pravin KachhadiyaDepartment of Electrical and Computer Engineering , University of Wisconsin Madison, Madison, USA.
Mauricio Araiza CanizalesDepartment of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI, USA.
Alison BrooksDepartment of Orthopedics and Rehabilitation, University of Wisconsin-Madison, Madison, WI, USA.
Haneesh KesariSchool of Engineering, Brown University, Providence, RI, USA.
Joseph AndrewsDepartment of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI, USA.
Traci SneddenCollege of Nursing, University of Colorado Anschutz Medical Campus, Aurora, CO, USA.
Peter FerrazzanoWaisman Center, University of Wisconsin-Madison, Madison, WI, USA.
Christian FranckDepartment of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI, USA.
Rika Wright CarlsenDepartment of Engineering, Robert Morris University, Moon Township, PA, USA. carlsen@rmu.edu.ORCID http://orcid.org/0000-0002-5743-1130

Funding

Office of Naval Research N00014-21-1-2044Office of the Vice Chancellor for Research and Graduate Education, University of Wisconsin-Madison 136-AAI3375
6 · The paper itself

Abstract

purposeTo study the relationship between soccer heading and the risk of mild traumatic brain injury (mTBI), we previously developed an instrumented headband and data-processing scheme to measure the angular head kinematics of soccer headers. Laboratory evaluation of the headband on an anthropomorphic test device showed good agreement with a reference sensor for soccer ball impacts to the front of the head. In this study, we evaluate the headband in measuring the full head kinematics of soccer headers in the field.

methodsThe headband was evaluated under typical soccer heading scenarios (throw-ins, goal-kicks, and corner-kicks) on a human subject. The measured time history and peak kinematics from the headband were compared with those from an instrumented mouthpiece, which is a widely accepted method for measuring head kinematics in the field.

resultsThe time-history agreement (CORA scores) between the headband and the mouthpiece ranged from 'fair' to 'excellent', with the highest agreement for angular velocities (0.79 ± 0.08) and translational accelerations (0.73 ± 0.05) and lowest for angular accelerations (0.67 ± 0.06). A Bland-Altman analysis of the peak kinematics from the headband and mouthpiece found the mean bias to be 40.9

conclusionsThe field evaluation of the instrumented headband showed reasonable agreement with the mouthpiece for some kinematic measures and impact conditions. Future work should focus on improving the headband performance across all kinematic measures.

Indexed as

HeadSoccerWearable Electronic DevicesAccelerationBiomechanical PhenomenaHumansMaleField validationInstrumented headbandMild traumatic brain injurySensor arraySoccer headers

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.