Evidence map›Paper›PMID 41826578›Full record

ArticleAnnals of biomedical engineering2026

Computational Modeling of Collateral Circulation and Arteriolar Vasodilation in Ischemic Tissue Perfusion.

Nolan Moreaux, Chang Min Lee, Bon-Kwon Koo, Keun-Hwa Jung, Jung-Kyu Han, Hyeyeon Chang, Hyun Jin Kim

Abstract read
In one paragraph

Article in Annals of biomedical engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Nolan MoreauxDepartment of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea.
Chang Min LeeDepartment of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea.
Bon-Kwon KooSeoul National University Hospital, Seoul, Republic of Korea.
Keun-Hwa JungSeoul National University Hospital, Seoul, Republic of Korea.
Jung-Kyu HanSeoul National University Hospital, Seoul, Republic of Korea.
Hyeyeon ChangKonyang University Hospital, Nonsan, Republic of Korea.
Hyun Jin KimDepartment of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea. kim.hyunjin@kaist.ac.kr.ORCID http://orcid.org/0000-0003-0358-4972

Funding

Ministry of Food and Drug Safety RS-2023-00215667Ministry of Science and ICT, South Korea RS-2022-NR070832Samsung Science and Technology Foundation SRFC-IT2401-04
6 · The paper itself

Abstract

purposeDespite substantial advances in computational cardiovascular modeling, simplifying assumptions often overlook key compensatory mechanisms. To better capture physiological responses under pathological conditions, we incorporate two essential compensatory mechanisms-collateral circulation and arteriolar vasodilation-into a multiscale blood perfusion simulation framework.

methodsCollateral vessels are stochastically generated to supply ischemic regions, with model parameters systematically varied to control vessel density, caliber, and spatial distribution. Arteriolar vasodilation is modeled to represent the combined response of vascular smooth muscle cells to local metabolic and hemodynamic stimuli. To assess their impact on perfusion, artificial stenoses are introduced into both an idealized geometry and a subject-specific cerebrovascular model.

resultsSimulation results across varying collateral configurations and vasodilation capacities demonstrate that perfusion enhancement from sub-resolution collateral vessels alone is limited and highly dependent on vessel caliber and density. In contrast, combining collateral flow with vasodilation produces a more pronounced improvement in tissue perfusion. These findings suggest that arteriolar vasodilation serves as the primary mechanism for ischemic compensation, with collateral circulation providing secondary support which is consistent with clinical observations.

conclusionThe proposed methods enable multiscale blood flow simulations while accounting for the main autoregulatory mechanisms. The models have been verified using literature data and are shown to provide accurate results.

Indexed as

Cerebrovascular CirculationCollateral CirculationModels, CardiovascularVasodilationAnimalsArteriolesComputer SimulationHumansArteriolar vasodilationBlood flow modelingCollateral circulationIschemiaPerfusion simulation

Identifiers

PMID41826578
PMCPMC13649848

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.