Evidence map›Paper›PMID 41823485›Full record

ArticleThe journal of extra-corporeal technology2026

The effect of surgical field suction flow rate and venous reservoir levels on gaseous microemboli transmission⋆.

Thomas Rath, Marisa Sugden, Edward Evans, Kyle Dana, Mitchell Rentschler, Charlotte Bolch, Nathaniel H Darban

Abstract read
In one paragraph

Article in The journal of extra-corporeal technology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Thomas RathCollege of Health Sciences, Midwestern University, 19555 N. 59th Avenue, Glendale, AZ 85308, USA.ORCID 0000-0002-5073-9255
Marisa SugdenCollege of Graduate Studies, Midwestern University, 19555 N. 59th Avenue, Glendale, AZ 85308, USA.
Edward EvansCardiovascular Perfusion Program, Lipscomb University, 1 University Park Dr, Nashville, TN 37204, USA.
Kyle DanaCollege of Health Sciences, Midwestern University, 19555 N. 59th Avenue, Glendale, AZ 85308, USA.
Mitchell RentschlerArizona College of Osteopathic Medicine, Midwestern University, 19555 N. 59th Avenue, Glendale, AZ 85308, USA.
Charlotte BolchOffice of Research & Sponsored Programs, Midwestern University, 19555 N. 59th Avenue, Glendale, AZ 85308, USA.
Nathaniel H DarbanCollege of Health Sciences, Midwestern University, 19555 N. 59th Avenue, Glendale, AZ 85308, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMinimizing Gaseous microemboli (GME) introduced into the CPB circuit can help alleviate neurologic injury. This study focuses on understanding how suction flow rate and the reservoir level can influence the introduction of GME past the venous reservoir during CPB.

methodsAn in vitro mock CPB loop filled with bovine blood was used to simulate adult CPB. A Gampt BCC-300 bubble detector measured bubble size, volume, and count at three locations: post-reservoir (venous), post-oxygenator/arterial filter (arterial), and the venous inlet to the reservoir (recirculation). Room air was added into the suction line at 200 mL/min and mixed with blood to simulate aerated suction return. Bubble transmission was measured for three minutes at three reservoir levels, 200 mL, 500 mL, and 1000 mL, and at four pump sucker flow rates: 25 RPM (0.32 L/min), 50 RPM (0.65 L/min), 75 RPM (0.99 L/min), and 100 RPM (1.32 L/min). GME count data were pooled from three commonly used, coated, disposable reservoirs/oxygenator combinations: Medtronic Affinity Fusion, Terumo CAPIOX FX25, and Sorin Inspire 8F.

resultsA total of 284 measurements were conducted, and the data from all reservoir manufacturers were analyzed and averaged. A statistically significant interaction was noticed between roller pump suction rate and reservoir level (p-value < 0.0001) at the venous sensor. As the suction flow rate increased, the reservoir level decreased, or a combination of the two occurred, a significant increase in GME count was observed at the post-reservoir sensor. Analysis of the GME count from the post-oxygenator/filter sensor revealed a significant increase as the suction flow rate increased from 25 RPM to 100 RPM.

conclusionA minimum effective suction flow rate and maximum practical reservoir level are recommended to prevent the transmission of GME through the cardiopulmonary bypass circuit and potentially to the patient. Care should be taken to continuously monitor these variables throughout the case and adjust them accordingly.

Indexed as

Cardiopulmonary BypassEmbolism, AirAnimalsCattleEquipment DesignSuctionCardiopulmonary bypassCardiotomy suctionGaseous microemboliPerfusionVenous reservoir

Identifiers

PMID41823485
PMCPMC12984039

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.