ArticleRadiation protection dosimetry2026
Assessing accuracy and artefacts in proton stopping power ratio images across four computed tomography imaging workflows using a head-sized electron density phantom.
Article in Radiation protection dosimetry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Medical physics in the Nordic countries: collaboration and future challenges - report from the Nordic Association for Clinical Physics 2026 Symposium.Acta oncologica (Stockholm, Sweden) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The efficacy of proton beam therapy is limited by stopping power ratio (SPR) prediction uncertainties in patient tissues. This study compared image artefacts and SPR prediction accuracy across a single-energy computed tomography (SECT) and three dual-energy computed tomography (DECT) workflows: SECT with a clinical Hounsfield look-up table (HLUT), two commercial DECT algorithms (DirectSPR and MMSim), and an in-house developed model applied to material density (MD) images, called MD-SPR. SPR images of a head-sized phantom with 24 inserts of tissue surrogate and non-tissue materials were evaluated for image artefacts and compared with measured reference SPRs of the inserts. The root-mean-square SPR differences for tissue surrogates were 0.011 (HLUT), 0.005 (DirectSPR), 0.007 (MMSim), and 0.005 (MD-SPR). For non-tissue materials, the differences were 0.167, 0.028, 0.034, and 0.011, respectively. These results indicate that DECT-based SPR prediction workflows, particularly MD-SPR, can reduce both image artefacts and range uncertainties, compared with a SECT-based HLUT workflow.