ArticleRadiation protection dosimetry2026
A comparison of dose between cone beam computed tomography and conventional computed tomography in broad beam geometry.
Article in Radiation protection dosimetry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
A unified computed tomography dose index (CTDI) which includes all scattered radiation was used to investigate the difference in absorbed dose to the patient between a computed tomography (CT) and a cone beam CT (CBCT). The unified CTDI, denoted CTDI300,w, was measured using a 100 mm pencil ionization chamber at three positions covering 300 mm at each of the five phantom slots in three CTDI body phantoms. The dose length product of a lumbar spine protocol for the modalities was comparable (CT: 153 mGycm, CBCT: 126 mGycm), though the normalized CTDI300,w for the CT was 4.6 times higher than for the CBCT. The comparison between CTDI300,w and the two dose indexes provided by the systems showed a substantial underestimation for both modalities. The most accurate, but also the most inconvenient method to compare absorbed dose is to use the CTDI300,w. Most important is to always use the same dose index.