Safety and performance of the Hydra self-expanding THV: 6 months outcomes from the GENESIS-II study.
Article in Indian heart journal. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07566624 (Spanish Prospective Registry of Hydra THV for Transcatheter Aortic Valve Implantation), which is not on this map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Spanish Prospective Registry of Hydra THV for Transcatheter Aortic Valve Implantation
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
aimThe Hydra THV incorporates an active release mechanism designed to facilitate the deployment of the supra-annular valve. The aim of the GENESIS-II study was to assess the safety and performance of Hydra THV at 6 months follow-up after treating severe aortic stenosis in patients at high surgical risk.
methodsThis prospective, multicenter, non-randomized, investigational study was conducted between November 2021 and November 2023. The study enrolled 40 patients with high surgical risk and symptomatic severe aortic stenosis from 19 sites across India. The primary safety endpoint of the study was cardiovascular mortality at 30 days, while the primary performance endpoint was device success, as defined by VARC-2.
resultsAmong the 40 patients, the mean age was 74.4 ± 6.7 years, 65% were male, and the mean Society of Thoracic Surgeons (STS) risk score was 3.5 ± 1.6%. The device had a success rate of 95%. At 6 months, there was one cardiovascular death (2.5 %). All-cause death was observed in 5% patients. The incidence of new permanent pacemaker implantation was 7.9%. There was a progressive enhancement in effective orifice area, from 0.6 ± 0.2 cm
conclusionThe results of 6 months follow-up after implantation of the Hydra THV with an active release mechanism in the GENESIS-II study demonstrated a high device success rate with favorable safety and performance of the device.