Evidence map›Paper›PMID 41817304›Full record

Observational studyRadiology. Cardiothoracic imaging2026

Precise Lung Density Quantification with a Physics-based CT Harmonizer.

Saman Sotoudeh-Paima, David A Lynch, Stephen M Humphries, Ehsan Samei, Ehsan Abadi

Abstract readMulticenter StudyObservational Study
In one paragraph

Observational study in Radiology. Cardiothoracic imaging, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Saman Sotoudeh-PaimaCenter for Virtual Imaging Trials, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University School of Medicine, 2424 Erwin Rd, Hock Plaza, Ste 302, Durham, NC 27705.ORCID 0000-0003-0170-2541
David A LynchDepartment of Radiology, National Jewish Health, Denver, Colo.ORCID 0000-0002-6329-2325
Stephen M HumphriesDepartment of Radiology, National Jewish Health, Denver, Colo.ORCID 0000-0002-5113-4530
Ehsan SameiCenter for Virtual Imaging Trials, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University School of Medicine, 2424 Erwin Rd, Hock Plaza, Ste 302, Durham, NC 27705.ORCID 0000-0001-7451-3309
Ehsan AbadiCenter for Virtual Imaging Trials, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University School of Medicine, 2424 Erwin Rd, Hock Plaza, Ste 302, Durham, NC 27705.ORCID 0000-0002-9123-5854

Funding

Genetic Epidemiology of COPDU01HL089897 · NHLBI · NATIONAL JEWISH HEALTH · PI CRAPO, JAMES D · 2007 to 2021
$56.9M
GENETIC EPIDEMIOLOGY OF COPD (COPD GENE) TASK A: STUDY VISIT 4, COLLECTION OF COPDGENE STUDY DATA ANDBIOSPECIMENS AND OVERSIGHT OF THE COPDGENE STUDY75N92023D00011 · NHLBI · NATIONAL JEWISH HEALTH · PI NEWMAN, LEE S · 2023 to 2025
$29.6M
Genetic Epidemiology of COPDU01HL089856 · NHLBI · BRIGHAM AND WOMEN'S HOSPITAL · PI SILVERMAN, EDWIN K · 2007 to 2021
$20.7M
TR&D Project 3: Virtual ReadersP41EB028744 · NIBIB · DUKE UNIVERSITY · PI Ehsan Samei · 2021 to 2026
$7.8M
Accuracy and Precision in CT Quantification of COPD Through Virtual Imaging TrialsR01HL155293 · NHLBI · DUKE UNIVERSITY · PI ABADI, EHSAN · 2021 to 2025
$2.2M
NHLBI NIH HHS 75N92023D00011NHLBI NIH HHS R01 HL155293NHLBI NIH HHS U01 HL089856NHLBI NIH HHS U01 HL089897NIBIB NIH HHS P41 EB028744
6 · The paper itself

Abstract

Purpose To develop a physics-based image harmonization method that transforms images into a reference quality index of noise, spatial resolution, and lung volume and to evaluate its performance for improving reproducibility of lung density measurement. Materials and Methods This retrospective analysis of Genetic Epidemiology of Chronic Obstructive Pulmonary Disease (COPDGene) study data included participants who underwent chest CT with full-dose (200 mAs) and reduced-dose (40-80 mAs) protocols during the same visit between November 2014 and July 2017. A harmonization algorithm was developed to reduce variations in lung density by adjusting spatial resolution, noise, and lung volume in sequence, aligning scans to a reference condition based on full-dose, soft-kernel reconstruction. The percentage of lung voxels less than -950 HU (LAA-950) and the 15th percentile of the lung density histogram (Perc15) were calculated from scans. Improvements in bias, limits of agreement, and reproducibility coefficients were evaluated, and harmonizer performance was compared with that of two existing techniques: volume-adjusted lung density (VALD) and median filtering followed by VALD (MF-VALD). Results A total of 1159 participants (mean age ± SD, 65 years ± 9; 586 male) were studied. Across all imaging conditions, the harmonization technique improved the Perc15 reproducibility coefficient 4.8-fold, from 35.6 HU ± 0.7 to 7.4 HU ± 0.2. The harmonizer outperformed VALD and MF-VALD across the full-dose and reduced-dose scans, with reproducibility coefficients improving from 32.4 HU ± 0.7 before harmonization to 30.1 HU ± 0.3 with VALD, 10.3 HU ± 0.3 with MF-VALD, and 7.7 HU ± 0.2 with the harmonizer. Conclusion This physics-based technique harmonized CT images to a reference quality index, improving the reproducibility of lung density metrics.

Indexed as

LungPulmonary Disease, Chronic ObstructiveTomography, X-Ray ComputedAgedAlgorithmsFemaleHumansMaleMiddle AgedReproducibility of ResultsRetrospective StudiesChronic Obstructive Pulmonary DiseaseCTLungPhysicsThorax

Identifiers

PMID41817304
PMCPMC13139913

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.